Product Short Description

Product Name:​ Yokogawa 2302-32-VLE-2 Multi-Function Measurement Module
Product Introduction:
The Yokogawa 2302-32-VLE-2 is a high-precision, multi-functional industrial measurement module that monitors voltage, current, power, and energy parameters within a single compact unit. It is engineered for integration into DCS, PLC, and energy management systems.

Description

Technical Specifications:
  • Manufacturer:​ Yokogawa
  • Measurement Range:
    • Voltage:​ 0–10 V DC
    • Current:​ 0–20 mA / 4–20 mA
    • Power:​ Active, reactive, and apparent power
  • Accuracy:​ ±0.05% of reading
  • Resolution:​ 16-bit
  • Communication:​ RS-485, Modbus RTU
  • Power Supply:​ 24 V DC (±10%)
  • Operating Temperature:​ –40 °C to +85 °C
  • Dimensions:​ 22.5 mm × 99.2 mm × 114.4 mm
  • Weight:​ 250 g
  • Certifications:​ CE compliant, industrial vibration and shock resistance
  • I/O Configuration:​ Analog inputs/outputs, digital I/O (expandable via modular design)
Functional Characteristics:
  • Single-module versatility reduces system complexity
  • ±0.05% accuracy with 16-bit resolution for detailed industrial process analysis
  • Rugged industrial-grade construction withstands extreme temperatures, vibration, and shock
  • RS-485 / Modbus RTU enables seamless integration with DCS, PLC, and energy management platforms
  • Modular expandability adapts to evolving I/O requirements
Working Principle:
The module samples incoming analog voltage or current signals through a 16-bit ADC. On-board DSP computes power and energy metrics from the digitized waveforms. Results are transmitted over the RS-485 Modbus RTU link to the host controller, which can poll multiple modules on a shared bus.
Application Scenarios:
  • Power management and energy monitoring
  • Machinery health monitoring
  • Distributed Control Systems (DCS)
  • Process automation and control
  • Integration with PLCs and SCADA systems
Installation Requirements:
  • Mount on standard DIN rail within a control cabinet
  • Provide 24 V DC (±10%) auxiliary power
  • Terminate the RS-485 bus with proper bias and termination resistors
  • Observe polarity for 4–20 mA and 0–10 V DC field signals
Usage Notes:
  • Maintain operating temperature within –40 °C to +85 °C
  • Ensure correct Modbus slave addressing to avoid bus conflicts
  • Calibrate periodically to sustain ±0.05% accuracy
  • Use shielded cable for analog inputs in high-noise environments

Reviews

There are no reviews yet.

Be the first to review “Yokogawa 2302-32-VLE-2”

Your email address will not be published. Required fields are marked *

View Related Products