Product Name: Yokogawa ADV569-P00 Electromagnetic Flow Transmitter
Product Introduction: The ADV569-P00 is an electromagnetic (mag) flow transmitter manufactured by Yokogawa Electric Corporation. It measures the volumetric flow rate of conductive liquids based on Faraday’s Law of Electromagnetic Induction. The “-P00” suffix indicates the standard pressure variant (typically ANSI 150 flange rating, up to 16 bar) with 4–20 mA output and HART 7 protocol.
Description
Technical Specifications:
- Type: Electromagnetic flow transmitter
- Process Connection: Flanged (DN10 – DN2000), wafer, or sanitary (tri-clamp)
- Process Pressure: Up to 16 bar (232 psi) — “P00” standard rating
- Process Temperature: -20°C to +180°C (standard liners); up to +250°C (PFA liner)
- Output: 4–20 mA + HART 7; pulse output optional
- Power Supply: 18–36 VDC or 85–265 VAC (2-wire or 4-wire)
- Accuracy: ±0.5% of reading (standard); ±0.2% (high-accuracy variant)
- Repeatability: ±0.1% of reading
- Conductivity Requirement: >5 µS/cm (minimum)
- Turndown Ratio: 1:100
- Protection Rating: IP67 / IP68 (submersible variants available)
- Liner Options: PTFE, PFA, rubber, polyurethane, ceramic
- Electrode Options: SUS316L, Hastelloy C, tantalum, titanium, platinum
Functional Features:
- Empty pipe detection
- Electrode adhesion diagnosis
- HART 7 communication
- Dual-frequency excitation for noise immunity
- Bi-directional flow measurement
- Totalizer function (built-in)
Performance Parameters:
- Response Time: 0.5 – 5 seconds (adjustable)
- Pressure Drop: Zero (no obstruction in pipe)
- MTBF: >150,000 hours
Material Composition:
- Tube: Carbon steel with PTFE/PFA lining; or stainless steel
- Electrodes: SUS316L, Hastelloy C, tantalum (per fluid compatibility)
- Housing: Aluminum alloy, epoxy-coated (IP67)
Structural Features: Inline flanged, wafer, or sanitary installation. No moving parts, no pressure drop. Compact transmitter head mounts directly on the sensor body. Weight: 4–45 kg depending on size.
Working Principle: A magnetic field is generated across the pipe by coils in the transmitter. As conductive fluid flows through the field, a voltage is induced proportional to flow velocity (Faraday’s Law: E = B × D × V). Electrodes detect this voltage, and the transmitter calculates volumetric flow rate.
Key Advantages: Zero pressure drop — ideal for large pipes. No moving parts — extremely low maintenance. Measures dirty, slurry, and corrosive fluids. 1:100 turndown.
Applicable Industries: Water/wastewater, chemical, food & beverage, pharmaceutical, mining, pulp & paper, oil & gas.
Model Series: Yokogawa ADMAG AXF / ADV569 Series