Product Short Description

Product Name​
NI SCXI-1327 High-Voltage Attenuator Terminal Block
Product Introduction​
The NI SCXI-1327 is a shielded SCXI terminal block​ with 100:1 attenuation and cold-junction sensing. It extends the input range of compatible SCXI analog modules to high-voltage measurements.

Description

Technical Specifications​
Part number:​ 777687-27, 185136A-01
Type:​ high-voltage attenuator terminal block
Screw terminals:​ 18
Signal terminals:​ 16, eight pairs
Attenuation ratio:​ 100:1
Extended range:​ ±250 Vrms or ±300 VDC with attenuation enabled
Input impedance with attenuation:​ 1 Mohm
Compatible modules:​ SCXI-1120, SCXI-1120D, SCXI-1121, SCXI-1125, SCXI-1126
Cold-junction sensor:​ thermistor
Thermistor output:​ 1.91 V at 0 °C to 0.58 V at 55 °C
Dimensions:​ 7.0 x 3.125 x 1.2 in.
Weight:​ 7 oz
Operating temperature:​ 0 to 50 °C
Storage temperature:​ -20 to 70 °C
Humidity:​ 5 to 90 percent noncondensing
Functional Features​
Per-channel attenuator enable switches​
Passive 100:1 resistive divider​
Built-in thermistor​ for temperature sensing
Shielded construction​ for industrial environments
Extends SCXI-1126 threshold range up to 300 V
Material And Structure​
Housing:​ metal-shielded terminal housing
Network:​ precision resistor divider network
Switches:​ toggle or DIP-style attenuator switches
Wiring:​ screw terminals for field signal wiring
Sensor:​ thermistor mounted on terminal plane
Working Principle​
The resistor network divides the high-voltage input by 100​ before it reaches the SCXI module. When attenuation is bypassed, the terminal block passes low-level signals directly. The thermistor output is converted in software to temperature for CJC or environment monitoring.
Application Scenarios​
High-voltage process monitoring​
Power-supply output measurement​
Motor drive signal acquisition​
Industrial thermocouple measurement​
Frequency or threshold measurement with SCXI-1126​
EMI-heavy factory measurements​
Installation Requirements​
Mount on a compatible SCXI analog input module​
Set attenuator switches before applying voltage​
Use 1 Mohm input-impedance awareness​ in calculations
Connect shields to chassis ground​
Verify module supports the selected channel mode
Usage Notes​
Do not​ apply high voltage with attenuator bypassed
Keep attenuation switches stable​ during measurement
Use shielded cable​ for high-voltage lines
Calibrate annually​ for demanding applications