Product Short Description
Product Name
NI SCXI-1327 High-Voltage Attenuator Terminal Block
Product Introduction
The NI SCXI-1327 is a shielded SCXI terminal block with 100:1 attenuation and cold-junction sensing. It extends the input range of compatible SCXI analog modules to high-voltage measurements.
Description
Technical Specifications
Part number: 777687-27, 185136A-01
Type: high-voltage attenuator terminal block
Screw terminals: 18
Signal terminals: 16, eight pairs
Attenuation ratio: 100:1
Extended range: ±250 Vrms or ±300 VDC with attenuation enabled
Input impedance with attenuation: 1 Mohm
Compatible modules: SCXI-1120, SCXI-1120D, SCXI-1121, SCXI-1125, SCXI-1126
Cold-junction sensor: thermistor
Thermistor output: 1.91 V at 0 °C to 0.58 V at 55 °C
Dimensions: 7.0 x 3.125 x 1.2 in.
Weight: 7 oz
Operating temperature: 0 to 50 °C
Storage temperature: -20 to 70 °C
Humidity: 5 to 90 percent noncondensing
Functional Features
Per-channel attenuator enable switches
Passive 100:1 resistive divider
Built-in thermistor for temperature sensing
Shielded construction for industrial environments
Extends SCXI-1126 threshold range up to 300 V
Material And Structure
Housing: metal-shielded terminal housing
Network: precision resistor divider network
Switches: toggle or DIP-style attenuator switches
Wiring: screw terminals for field signal wiring
Sensor: thermistor mounted on terminal plane
Working Principle
The resistor network divides the high-voltage input by 100 before it reaches the SCXI module. When attenuation is bypassed, the terminal block passes low-level signals directly. The thermistor output is converted in software to temperature for CJC or environment monitoring.
Application Scenarios
High-voltage process monitoring
Power-supply output measurement
Motor drive signal acquisition
Industrial thermocouple measurement
Frequency or threshold measurement with SCXI-1126
EMI-heavy factory measurements
Installation Requirements
Mount on a compatible SCXI analog input module
Set attenuator switches before applying voltage
Use 1 Mohm input-impedance awareness in calculations
Connect shields to chassis ground
Verify module supports the selected channel mode
Usage Notes
Do not apply high voltage with attenuator bypassed
Keep attenuation switches stable during measurement
Use shielded cable for high-voltage lines
Calibrate annually for demanding applications
NI lists the terminal block as obsolete





Reviews