Product Short Description

Product Name​
NI SCXI-1102 32-Channel Voltage Input Module
Product Introduction​
The NI SCXI-1102 is a SCXI signal-conditioning input module​ for low-level voltage, thermocouple, millivolt and current-loop measurements. It is used with an SCXI chassis and compatible NI DAQ device.

Description

Technical Specifications​
Channels:​ 32 differential analog inputs
Input ranges:​ ±100 mV gain 100, ±10 V gain 1
Input coupling:​ DC
Input impedance:​ 1 Gohm powered, 10 kohm powered off
Bandwidth:​ 2 Hz
Overvoltage protection:​ ±42 V powered
Maximum sampling rate:​ 333 kS/s aggregate, system dependent
Nonlinearity:​ 0.005 percent of full scale
CMRR 50 to 60 Hz:​ 110 dB
Output range:​ ±10 V
Rear connector:​ 50-pin
Dimensions:​ 1.2 x 6.8 x 7.4 in.
Weight:​ 611 g
Operating temperature:​ 0 to 50 °C
Storage temperature:​ -20 to 70 °C
Functional Features​
Per-channel instrumentation amplifier​
Hardware low-pass filtering​
Cold-junction sensor channel​ for thermocouple scanning
Multiplexed output​ to DAQ device
Compatible with SCXI-1300, SCXI-1303, SCXI-1308, SCXI-1310​ terminal blocks
Material And Structure​
Faceplate:​ metal-front SCXI module
Board:​ PCB with precision amplifiers and multiplexer
Connector:​ 50-pin rear signal connector
Front interface:​ screw-terminal or isothermal terminal block
Working Principle​
Each input passes through protection, gain and filtering stages. The module multiplexes the 32 differential channels plus cold-junction sensor input to the connected DAQ device. Software corrects offset and gain using stored calibration constants.
Application Scenarios​
Thermocouple temperature measurement​
Environmental chamber monitoring​
Low-level voltage acquisition​
Millivolt sensor reading​
Process signal monitoring​
4 to 20 mA measurement​ with shunt or terminal block support
Installation Requirements​
Install in a compatible NI SCXI chassis​
Connect supported DAQ device through backplane or cable
Use isothermal terminal block such as SCXI-1303​ for thermocouples
Allow 20-minute warm-up​ for stable accuracy
Use shielded cabling​ for noisy environments
Usage Notes​
Wait about 3 seconds after gain change​ for 2 Hz filter settling
Do not​ exceed ±42 V input protection limit
Recalibrate annually​
Avoid condensation and electrostatic discharge
NI lists the module as obsolete, but service providers still support it