Product Short Description

Product Name​
505E Turbine Control (Digital Governor for Steam Turbines)
Product Introduction​
The Woodward 9907-167 is a 505E-series digital turbine controller specifically designed for extraction/admission steam turbines. It provides integrated control of main steam valve and extraction valve, with decoupled speed and extraction pressure regulation. The unit features a NEMA 4 panel-mounted enclosure with an integrated operator control panel (OCP).

Description

Technical Specifications​
  • Supply Voltage: 18–32 V DC (rated 24 V DC)
  • Power Consumption: 77 VA
  • Enclosure: NEMA 4 panel-embedded, front panel waterproof and dustproof
  • Operating Temperature: −20 °C to +65 °C
  • Storage Temperature: −40 °C to +85 °C
  • Certifications: CE, UL/cUL, Class I Div 2
  • Dimensions: 356 mm (L) × 279 mm (H) × 102 mm (D)
  • Weight: 4.35 kg
  • Digital Inputs: 16 (6 fixed-function + 10 programmable)
  • Relay Outputs: 8 passive contacts (3 fixed trip/alarm/run + 5 programmable), 250 V AC / 5 A
  • Analog Outputs: 6 isolated 4–20 mA
  • Analog Inputs: Multiple 4–20 mA / 0–10 V
  • Speed Input: Magnetic pulse pickup compatible, 0–6000 RPM, dual-channel redundant
  • Communications: RS-232, RS-422, RS-485 Modbus RTU (three isolated ports)
Functional Features​
  • Dual independent actuator driver outputs (4–20 mA or 20–160 mA selectable):
    • Output #1 → main steam governor valve
    • Output #2 → extraction/admission valve
  • Closed-loop speed control: isochronous (islanded), droop (paralleled), and multi-unit load distribution.
  • Extraction/admission pressure composite regulation — decouples speed from extraction pressure.
  • Multi-limit protection: valve position limits, min/max load, speed limits, extraction pressure limits.
  • Automatic start-up logic: acceleration, warm-up, critical-speed bypass, coast-down ramp, overspeed protection (103% / 110% two-stage).
  • Fault diagnostics: MPU open-wire, actuator short-circuit, AI loss, power failure, relay self-check with event logging.
  • Integrated OCP with 2-line text display for local configuration and monitoring.
Application Scenarios​
  • Cogeneration (CHP): Extraction steam turbines balancing power generation and process steam supply.
  • Back-pressure / Admission Turbines: Simultaneous control of inlet and extraction valves.
  • Industrial Drive Turbines: Turbines driving compressors or pumps in refinery and chemical plants.
Working Principle​
The 505E receives speed feedback from dual MPUs and process signals (extraction pressure, load, etc.) via analog inputs. Its 32-bit microprocessor executes PID control algorithms to regulate speed and extraction pressure independently. Two actuator outputs drive the main and extraction valves. Communication ports interface with DCS/PLC for remote monitoring and control.
Installation Requirements​
  • Panel-cutout mount in a NEMA 4 enclosure front.
  • Provide 24 V DC (18–32 V) power with correct polarity.
  • Connect MPU speed sensors with proper shielding; observe phasing.
  • Wire actuator outputs to Woodward EG/PGA actuators or 4–20 mA servo valves.
  • Connect analog I/O and digital I/O per terminal assignment in the 505E manual.
  • Establish RS-485 Modbus link to DCS/PLC; RS-232 for local PC configuration.
Usage Precautions​
  • Wear ESD grounding strap when handling the module.
  • Verify all field wiring matches signal type (4–20 mA or 0–10 V).
  • Do not exceed supply voltage range (18–32 V DC).
  • Ensure proper ventilation; do not block front panel.
  • Periodically review fault logs via OCP.
  • Keep firmware updated through RS-232 using Woodward software.