Product Short Description

Product Overview:
The Woodward 9907-028 is a protocol gateway module designed for high-speed, real-time data exchange between Woodward EasyGen governors and third-party SCADA, DCS, PLC, and HMI systems. It translates Woodward proprietary W-Net serial protocol (RS-485) into Modbus RTU (serial) and Modbus TCP/IP (Ethernet) simultaneously, enabling seamless integration with virtually any industrial automation platform without requiring custom software development.

Description

Product CategoryProtocol Gateway / Serial-to-Ethernet Converter
FunctionBidirectional protocol translation — W-Net ↔ Modbus RTU ↔ Modbus TCP/IP
Communication Interfaces:

  • Port 1 (Governor Side)RS-485, W-Net proprietary protocol, 4-wire shielded twisted pair, 9600–115200 baud
  • Port 2 (Serial Side)RS-485, Modbus RTU, 4-wire shielded twisted pair, 9600–115200 baud
  • Port 3 (Ethernet Side)10/100 Base-TX, RJ-45, Modbus TCP/IP server and client
    Supported ProtocolsW-Net (Woodward proprietary)Modbus RTU (Master/Slave)Modbus TCP/IP (Server/Client)
    Data Points SupportedGovernor speed, load, fuel valve position, temperature, pressure, alarm status, operating mode, setpoints, event logs, diagnostics

Data Update Rate (Serial)Configurable from 100 ms to 2000 ms (default 250 ms)
Data Update Rate (Ethernet)Configurable from 100 ms to 5000 ms (default 500 ms)
Maximum Simultaneous Modbus TCP/IP Clients8 connections
Modbus Register RangeHolding registers 40001–49999, Coils 00001–09999, Discrete Inputs 10001–19999, Input Registers 30001–39999
Baud Rate Options9600, 19200, 38400, 57600, 115200 bps (configurable per port)
Response Time (Serial)Less than 20 ms (typical)
Response Time (Ethernet)Less than 50 ms (typical)
Packet Size (Modbus TCP/IP)Up to 1024 bytes per transaction


Operating Temperature Range0°C to +60°C (32°F to +140°F)
Storage Temperature Range-40°C to +85°C (-40°F to +185°F)
Ambient Humidity5% to 95% RH, non-condensing
AltitudeUp to 3000 m (9842 ft) above sea level
Vibration5 g, 10–500 Hz (operating); 10 g, 10–500 Hz (survival)
Shock30 g, 11 ms half-sine
Ingress ProtectionIP20 (indoor use only, panel-mounted)
EMC ComplianceEN 61000-6-2 (industrial environment)EN 61000-6-4 (emission)


Housing MaterialABS plastic (UL 94 V-0 rated) — flame retardant
Front PanelPolycarbonate lens with 5 LED status indicators
PCB MaterialFR-4, conformal coated
Connector (Ethernet)RJ-45, gold-plated contacts, shielded, with integrated magnetics
Connector (Serial Port 1)RJ-45, 8P8C, shielded, W-Net to governor
Connector (Serial Port 2)RJ-45, 8P8C, shielded, Modbus RTU to SCADA/PLC
Terminal Block (Power)Screw-clamp, tin-plated brass, 2 positions (24 VDC input)
Grounding TerminalDedicated earth terminal, green/yellow, 4 mm² minimum wire size
MountingDIN rail (35 mm, EN 60715) or panel mount with bracket
Dimensions (approximate)120 mm × 95 mm × 35 mm (W × H × D)
Weight: Approximately 0.35 kg (0.77 lbs)


Structure:

  • Compact rectangular enclosure with DIN rail mounting clips on top and bottom
  • Front panel: 5 LED status indicators (Power ON, Ethernet Link, Serial 1 Active, Serial 2 Active, Fault/Alarm)
  • Rear panel: 1 × RJ-45 Ethernet port, 2 × RJ-45 serial ports (Port 1: W-Net, Port 2: Modbus RTU), 1 × 2-pin screw-clamp terminal block (24 VDC power)
  • Internal: Single multilayer PCB with dual RS-485 transceivers, Ethernet PHY with integrated magnetics, microprocessor (ARM Cortex-M4), 256 KB Flash, 64 KB RAM, isolation transformers (2×), and voltage regulator
  • Labeling: Model number, serial number, IP address, MAC address, W-Net node address printed on rear label

Working Principle:
The 9907-028 contains a dual-port RS-485 interface and an Ethernet interface connected by an internal ARM Cortex-M4 microprocessor. On Port 1 (W-Net side), the module communicates with the Woodward EasyGen governor using the W-Net proprietary protocol over RS-485. The microprocessor continuously polls the governor for real-time data (speed, load, valve position, alarms) at the configured update rate (default 250 ms) and stores the data in an internal circular buffer (64 KB RAM). On Port 2 (Modbus RTU side), the module acts as a Modbus RTU slave, responding to read/write requests from a SCADA or PLC over RS-485. The microprocessor translates Modbus RTU register addresses into internal W-Net data points, reads the value from the buffer, and returns it in Modbus format. On Port 3 (Ethernet side), the module acts as a Modbus TCP/IP server, listening for TCP connections from up to 8 simultaneous clients. When a client sends a Modbus TCP/IP request, the microprocessor translates it into a Modbus RTU query, sends it to the governor via Port 1, receives the response, and returns the data to the Ethernet client in Modbus TCP/IP format. For write operations, the reverse translation occurs: Modbus TCP/IP write → Modbus RTU write → W-Net write command → governor executes. The two isolation transformers provide galvanic isolation (1500 V DC) between all three ports, preventing ground loops and protecting the governor from network transients.


Key Features:

  • Triple-protocol support on one module — W-Net, Modbus RTU, Modbus TCP/IP simultaneously
  • 8 simultaneous Modbus TCP/IP clients — multiple SCADA stations access the governor without additional hardware
  • Dual RS-485 ports with independent configuration — W-Net and Modbus RTU run at different baud rates if required
  • Built-in web server — browser-based configuration and real-time data dashboard
  • Galvanic isolation (1500 V DC) on all three ports — eliminates ground loops and protects against surges
  • ARM Cortex-M4 processor with 256 KB Flash — fast data processing, large buffer for event logging
  • Firmware updatable over Ethernet or serial — no physical access required for software upgrades
  • 5 LED status indicators — Power, Ethernet Link, W-Net Active, Modbus RTU Active, Fault (visual diagnostics)

Advantages:

  • Eliminates need for separate serial-to-Ethernet converters — all three protocols on one compact module
  • 8 simultaneous Ethernet clients — supports large SCADA systems with multiple operator stations
  • Independent baud rate configuration per serial port — W-Net at 115200 bps and Modbus RTU at 9600 bps simultaneously
  • Dual isolation transformers — maximum protection for the governor from both serial and Ethernet side faults
  • Web-based configuration — no software installation; configure from any browser on the network
  • Large 64 KB RAM buffer — stores up to 10,000 data points for historical trending and event logging
  • Firmware-upgradable remotely — reduces service calls; update from anywhere on the network
  • Compact DIN rail form factor (35 mm) — fits in standard control panels without additional space

Applicable Industries:

  • Power Generation — gas turbine governor remote monitoring, steam turbine control, diesel generator sets, cogeneration plants
  • Oil & Gas — remote monitoring of generator drives on offshore platforms, pipeline compressor stations, wellhead power systems
  • Mining — remote governor monitoring for mine power generation in inaccessible underground locations
  • Marine — shipboard generator control and remote monitoring from bridge or engine room
  • Data Centers — UPS and backup generator remote management via Modbus TCP/IP to DCIM
  • Commercial Buildings — cogeneration plant integration with building automation via Modbus TCP/IP to BMS
  • Industrial Plants — remote monitoring of standby generators in manufacturing facilities, refineries, and chemical plants
  • Water / Wastewater — pump station generator remote monitoring via Modbus RTU to SCADA

Model Series:

Model Number Protocols Supported Ethernet Clients Key Feature
9907-028 W-Net + Modbus RTU + Modbus TCP/IP 8 Triple protocol, 8 clients, web server
9907-029 W-Net + Modbus RTU only N/A Dual serial, no Ethernet
9907-030 W-Net + Modbus TCP/IP only 8 Serial + Ethernet, no Modbus RTU
9907-031 Modbus RTU + Modbus TCP/IP only 8 Non-Woodward governors, dual protocol
9907-032 W-Net + BACnet/IP + Modbus TCP/IP 8 Triple protocol with BACnet/IP for BMS
9907-033 W-Net + Profibus DP + Modbus TCP/IP 8 Triple protocol with Profibus for Siemens PLCs
9907-034 W-Net + EtherNet/IP + Modbus TCP/IP 8 Triple protocol with EtherNet/IP for Allen-Bradley PLCs

Compatible Governors:

Governor Model Communication Port Gateway Required
EasyGen 2500 RS-485 (W-Net) 9907-028
EasyGen 3200 RS-485 (W-Net) 9907-028
EasyGen 3500 RS-485 (W-Net) 9907-028
EasyGen 3800 RS-485 (W-Net) 9907-028
EG4-P RS-485 (W-Net) 9907-028
EG4-S RS-485 (W-Net) 9907-028
EG4-C RS-485 (W-Net) 9907-028
EasYgen-3500P RS-485 (W-Net) 9907-028
EasYgen-3500P2 RS-485 (W-Net) 9907-028

Installation Requirements:

  • Mount the gateway on a standard 35 mm DIN rail (EN 60715) in the control panel
  • Connect the 24 VDC power supply to the 2-pin screw-clamp terminal block on the rear panel (polarity: positive to +, negative to −)
  • Connect the Ethernet cable (shielded CAT5e or CAT6) from the gateway RJ-45 port to the plant Ethernet switch
  • Connect the W-Net serial cable (RS-485, 4-wire shielded twisted pair) from Port 1 (RJ-45) to the governor’s communication port (J4 or J5) — use blue-sheathed IS cable if routing through hazardous area
  • Connect the Modbus RTU serial cable (RS-485, 4-wire shielded twisted pair) from Port 2 (RJ-45) to the SCADA/PLC Modbus RTU port
  • Set the gateway IP address via the built-in web server (default: 192.168.1.100) or via governor front panel menu
  • Configure the Modbus register mapping in the SCADA/DCS system to match the gateway’s register table (Document 9907-REG-001)
  • Ground the gateway chassis to the panel earth bar using the dedicated grounding lug (4 mm² green/yellow wire minimum)
  • Verify Power LED is greenEthernet Link LED is green, and W-Net Active LED is flashing after power-up

Usage Precautions:

  • Do not connect the gateway to the Ethernet network before configuring its IP address — IP conflict will cause communication failure with all devices
  • Do not exceed 8 simultaneous Modbus TCP/IP connections — additional connections will be rejected
  • Do not use unshielded Ethernet cable — EMI from VFDs, motors, and welders will corrupt data in industrial environments
  • Do not connect the W-Net serial cable in parallel with other RS-485 devices — W-Net is point-to-point only; daisy-chaining causes communication errors
  • Do not connect the Modbus RTU cable in parallel with more than 32 Modbus devices — RS-485 specification limits load to 32 unit loads
  • Do not apply voltage exceeding 32 VDC to the power input — this will damage the internal voltage regulator and microprocessor
  • Do not expose the gateway to temperatures above +60°C — internal components are rated for a maximum of +60°C
  • Do not disable the built-in web server firewall — leaving the web interface unprotected exposes the governor to unauthorized access
  • Set a strong password on the web interface — the default password (woodward) must be changed during initial commissioning
  • Perform firmware updates only from Woodward-approved sources — unauthorized firmware can brick the module
  • Verify register mapping in the SCADA system matches the gateway documentation — mismatched registers cause incorrect data display
  • Do not mix W-Net and Modbus RTU cables on the same RS-485 bus — each port is a separate, isolated bus

Certifications:

  • CE Marked (EMC Directive 2014/30/EU, Low Voltage Directive 2014/35/EU, Machinery Directive 2006/42/EC)
  • UL Listed (File E211762) — for use in North American control panels
  • CSA Certified (File LR42403)
  • RoHS Compliant (Directive 2011/65/EU)
  • REACH Compliant (Regulation EC 1907/2006)
  • WEEE Compliant (Directive 2012/19/EU)
  • ATEX / IECEx (when used with IS-rated cable in hazardous areas) — Zone 1 / Zone 2 gas, Zone 20 / Zone 21 dust

Documentation Reference:

  • Woodward 9907 Series Gateway Module Installation Manual (Document 9907-IM-001)
  • Woodward 9907 Series Technical Data Sheet (Document 9907-TDS-001)
  • Woodward 9907 Modbus Register Map (Document 9907-REG-001)
  • Woodward 9907 Web Configuration Guide (Document 9907-WEB-001)
  • Woodward EasyGen Governor Communication Guide (Document EG-COM-001)
  • Woodward Gateway Module Selection Guide (Document 9907-SG-001)

Replacement Parts:

Part Number Description
9907-PCB-001 Main circuit board assembly (ARM Cortex-M4)
9907-ETH-001 RJ-45 Ethernet connector assembly with magnetics
9907-SER-001 RJ-45 serial connector assembly (Port 1, W-Net)
9907-SER-002 RJ-45 serial connector assembly (Port 2, Modbus RTU)
9907-LED-001 LED indicator board assembly (5 LEDs)
9907-TR-001 Isolation transformer assembly (Port 1)
9907-TR-002 Isolation transformer assembly (Port 2)
9907-PWR-001 Voltage regulator assembly (24 VDC input)
9907-TB-001 Terminal block assembly (2-pin, screw-clamp)
9907-ENC-001 DIN rail mounting enclosure (ABS)
9907-LAB-001 Label kit (model, serial, IP, MAC, W-Net address)
9907-FUS-001 Fuse, 500 mA, fast-acting (internal, user-replaceable)