Description
Product Name and Category
MOVIDRIVE B Size 0 Drive
It is a basic drive unit with an application variant. Available documentation identifies it as part number 0005-5A3-4-0T.
Product Introduction
The MDX61B is a compact industrial drive intended to control AC motors across a range of speed and torque requirements. The size 0, 0005 variant supports a rated motor power of 0.55 kW. The drive is intended for cabinet installation and can be expanded with option cards for encoders, I/O, safety, and industrial communication.
Technical Specifications
- Rated motor power: 0.55 kW
- Recommended motor power for variable torque: 0.75 kW
- Nominal supply voltage: 3 × AC 380–500 V
- Line frequency: 50–60 Hz ±5%
- Nominal line current at 3 × AC 400 V: 1.8 A
- Apparent output power: 1.4 kVA
- Nominal output current at 3 × AC 400 V: 2.0 A
- Continuous output current at 4 kHz switching: 2.5 A
- Continuous output current at 8 kHz switching: 2.0 A
- Maximum output frequency: 599 Hz
- Speed range: –6000 to +6000 min⁻¹
- Adjustable PWM frequencies: 4, 8, 12, and 16 kHz
- Power loss at rated output: 42 W
- Cooling airflow: 3 m³/h
- Terminal conductor cross-section: 4 mm²
- Conductor end sleeve standard: DIN 46228
- Terminal tightening torque: 0.6 Nm
- Dimensions: 45 × 317 × 260 mm
- Mass: 2.0 kg
Functional Features
- Four-quadrant operation.
- Motor and generator-mode capability.
- Internal current limiting.
- Adjustable PWM switching frequency.
- Separable terminal strips for wiring.
- Expansion options for encoders, I/O, communication, safety, and control functions.
Application Scenarios
- Conveyor and material-handling systems.
- Pumps and fans.
- Mixing, winding, and process machines.
- Hoisting and travel drives where applicable.
- Packaging, assembly, and general industrial automation.
Performance Parameters
- Current limit: 200% of rated output current
- Duration of the current limit depends on capacity utilization.
- Minimum permissible braking resistance for four-quadrant operation: 68 Ω
- Speed resolution across the full range: 0.2 min⁻¹
Material Composition
No bill of materials was located for this exact serial/configuration. The drive enclosure and chassis are typical industrial metal construction, while internal assemblies include printed circuit boards, power semiconductors, capacitors, terminals, and heat-management components. These are general family characteristics and are not a confirmed material declaration.
Structural Characteristics
The unit is a book-style, cabinet-mounted drive with removable power and control terminal strips. It contains a mains section, DC-link and power stage, control electronics, operator interface area, and expansion-card option slot. Exact terminal assignments must be taken from the unit nameplate and the relevant manual.
Working Principle
The drive converts incoming three-phase AC power to DC and then uses controlled PWM switching to produce variable-voltage, variable-frequency AC power for the motor. Control electronics regulate output frequency, voltage, current, and torque to achieve the required speed or torque characteristic. Four-quadrant capability allows controlled motoring and regenerative behavior within the design limits.
Installation Requirements
- Mount vertically inside a suitable control cabinet.
- Maintain the clearances shown in the SEW documentation.
- Ensure adequate enclosure ventilation and cooling airflow.
- Install protective conductors and branch-circuit protection according to national codes and the SEW manual.
- Connect input power, motor output, control voltage, and option cards strictly according to the unit schematic.
- Use separable terminal strips and torque terminals to 0.6 Nm unless the documentation states otherwise.
Usage Precautions
- Only qualified personnel should install, commission, or repair the drive.
- Verify the supply is 3 × AC 380–500 V before connection.
- Observe all warnings relating to DC-link energy and high-voltage contact hazard.
- Reduce system and output currents by 20% when operating at 3 × AC 500 V.
- Do not exceed the minimum braking resistance of 68 Ω for four-quadrant operation.
- Maintain the required ambient temperature and avoid moisture, conductive dust, and poor ventilation.
- Check derating requirements when increasing the PWM frequency or operating at high altitude.