Product Short Description
Product Name: Bosch Rexroth Indramat DKC03.3 EcoDrive03 AC Servo Drive Controller
Product Overview: The DKC03.3 is the third-generation hardware platform in the DKC EcoDrive03 series. It features advanced communication capabilities (PROFIBUS / Analog) and expanded firmware functionality, designed for demanding industrial automation environments.
Description
Technical Specifications:
- Typical Model: DKC03.3-100-7-FW (~12 kW, 3×400–480 VAC, 100 A, PROFIBUS/Analog, internal fan)
- Available Current Ratings: 040 / 100 / 200 A frames
- DC-Bus Nominal Voltage: 700 V
- Rated Input Voltage: 200–480 V (±10%), 50–60 Hz, 1× or 3× AC
- Control Input Voltage: 24 V DC
- Control Voltage Power Consumption: 26 W (for 100 A frame)
- Continuous Current (4 kHz): 40 A (040) / 85 A (100)
- Maximum Output Current: 100 A / 200 A
- Maximum Output Frequency: 1000 Hz (4 kHz PWM) / 800 Hz (8 kHz PWM)
- Maximum Output Voltage: 800 V
- Protection Class: IP20
- Device Dimensions: 105 mm (W, 040/100) or 230 mm (W, 200) × 360 mm (H) × 261 mm (D)
- Weight: 5.7 kg (040) / 9.7 kg (100) / 19.5 kg (200)
- Operating Temperature: 45 °C max (nominal), 55 °C max (reduced data)
- Standards: UL 508 C listed, CSA C22.2 No. 14-05
Functional Features:
- Advanced PROFIBUS and analog communication interfaces
- Expanded firmware capabilities for complex motion functions
- Up to 32 position recipes via I/O option card
- Internal blower cooling for power section thermal stability
- Bidirectional motor control for single- and multi-axis configurations
Structural Characteristics: Modular connectors (X1–X21) for control voltage, feedback, communication, and I/O. The drive includes firmware module slot, contact protection, and a dynamic brake (Zks) resistor of 6 Ω.
Application Scenarios: Packaging, printing, CNC machinery, material handling, and high-load continuous-motion environments.
Installation Requirements:
- Minimum top clearance: 150 mm; bottom clearance: 80 mm
- Maximum installation elevation: 1000 m
- Branch circuit protection: 20 A (040) / 70 A (100/200) fuse per UL
- Use 60/75 °C copper wire only, class 1 wire
- Required wire size per UL 508 A
Usage Notes:
- Firmware must be purchased separately and loaded during commissioning
- Default communication mode is SERCOS; analog mode requires “AN” option card in slot 1 and parameter changes (P-0-0011 set to “Analog”)
- Fault relay (X3.12–X3.14) should be wired into E-Stop loop for safety
- Ensure 24 V enable signal (X3.1) is held high to activate power stage
- Do not enter service area with pacemakers or metal implants