Product Short Description

Product Name:​ ProSoft 3100-MCM Modbus Communication Module for PLC-5
Product Introduction:
The ProSoft 3100-MCM is a Modbus Master/Slave communication module developed for Allen-Bradley PLC-5 processors. It enables Rockwell Automation PLC systems to communicate directly with Modbus-compatible devices including drives, analyzers, meters, and third-party control equipment, extending the life of legacy PLC-5 installations.

Description

Technical Specifications:
  • Manufacturer:​ ProSoft Technology
  • Compatible Controllers:​ Allen-Bradley PLC-5
  • Module Type:​ Modbus communication interface
  • Supported Protocols:​ Modbus RTU, Modbus ASCII
  • Operating Modes:​ Master or Slave (independent per port)
  • Communication Ports:​ 2 × DB-25 female
  • Electrical Standards:​ RS-232, RS-422, RS-485 (configurable)
  • Baud Rate Range:​ 300 to 19.2 kbps
  • Data Format:​ 8 data bits, selectable parity, 1 stop bit
  • Maximum Nodes:​ Up to 32 nodes per RS-485 segment
  • Power Supply:​ 5 VDC from PLC backplane
  • Operating Temperature:​ 0 °C to +60 °C
  • Storage Temperature:​ -40 °C to +85 °C
  • Humidity:​ 5–95% non-condensing
  • Lifecycle Status:​ Discontinued / legacy product
Functional Features:
  • Dual independent ports allow simultaneous Master and Slave operation
  • Supports both Modbus RTU and Modbus ASCII protocols
  • Configurable via DIP switches and ProSoft configuration tools
  • Draws power directly from the PLC-5 backplane — no external supply needed
  • LED indicators provide module and communication status
  • Bridges legacy PLC-5 systems with modern Modbus field devices
Application Scenarios:
  • Integration of Modbus RTU/ASCII field devices into existing PLC-5 systems
  • Process automation requiring connectivity to Modbus drives and analyzers
  • Utility systems linking meters and third-party controls to PLC-5
  • Legacy system modernization without replacing the core controller
Installation Requirements:
  • Insert directly into a PLC-5 chassis slot
  • Verify backplane power supply has sufficient headroom for the module draw
  • Configure DIP switches for baud rate, parity, and node address
  • Use high-quality shielded twisted-pair cabling for RS-485 networks
  • RS-232 cable runs limited to approximately 15 meters; RS-485 extends to 1200 meters
Usage Notes:
  • Port 1 can be set as Master while Port 2 acts as Slave, or any combination thereof
  • Proper termination resistors are required on RS-485 multi-drop networks
  • As a discontinued product, source from authorized surplus suppliers with warranty
  • Configure using ProSoft configuration tools for precise protocol behavior