Product Short Description
Product Name
Stationary Ultrasonic Clamp-On Flowmeter
Product Introduction
The OPTISONIC 6300 is a stationary clamp-on ultrasonic flowmeter for liquid applications. It is installed on the outer wall of the pipeline without process interruption, providing accurate flow measurement for retrofitting and temporary measurement scenarios. It adopts dual-beam X-mode measurement technology for high reliability and accuracy.
Description
Technical Specifications
- Measuring Principle: Transit-time ultrasonic method
- Pipe Diameter Range: DN15 to DN400 (1/2″ to 16″) depending on sensor size
- Flow Velocity Range: 0.1 m/s to 20 m/s (turn-down ratio 200:1)
- Measurement Accuracy: ±1% of reading (≥DN50, 0.5-20 m/s); ±5 mm/s (0.1-0.5 m/s)
- Repeatability: ±0.2% of reading
- Medium Temperature: -40°C to +200°C (XT version)
- Protection Rating: IP68 / NEMA 6P (optional)
- Output Signals: 4-20 mA, pulse, status outputs
- Communication: HART, Modbus, PROFIBUS PA (optional)
- Power Supply: 24 VDC / 110-230 VAC
- Certification: ATEX, IECEx for hazardous areas (optional)
Functional Features
- Clamp-on installation without process shutdown or pipe cutting
- Dual-beam X-mode measurement for enhanced accuracy and reliability
- Factory calibrated sensors for immediate commissioning
- Integrated thermal energy calculation function
- Advanced diagnostics according to NAMUR NE 107
- Stainless steel rail mounting system
- Compatible with various pipe materials and linings
Application Scenarios
- Water and wastewater treatment flow monitoring
- Chemical and petrochemical process flow measurement
- HVAC and building energy management
- Food and beverage production flow control
- Pipeline leak detection and verification
- Retrofitting of existing pipe systems without flowmeters
- Temporary flow measurement for performance testing
Material & Construction
- Sensor Housing: Aluminum or stainless steel (optional)
- Mounting Rail: Stainless steel clamping system
- Transducer Face: Acoustic matching wear-resistant material
- Signal Converter: Aluminum die-cast housing with powder coating
- Cable: Shielded polyurethane cable
Structural Features
- Rail-based sensor mounting system for precise alignment
- Compact sensor design for small pipe diameters
- Wall or pipe mountable signal converter
- Removable terminal covers for easy wiring
- Integrated display and operation buttons on converter
Working Principle
It operates on the transit-time difference principle. Two ultrasonic transducers are mounted on the pipe wall at an angle to each other. They alternately emit and receive ultrasonic pulses that travel diagonally through the liquid. The pulse traveling downstream moves faster than the one traveling upstream. The controller measures the time difference between the two directions and calculates the average flow velocity of the liquid, then derives the volume flow rate based on the pipe cross-sectional area.
Installation Requirements
- Install on straight pipe sections with minimum 10DN upstream and 5DN downstream straight length
- Ensure full pipe flow during measurement
- Select appropriate sensor size according to pipe diameter
- Apply acoustic coupling compound between sensor and pipe wall
- Avoid installation near valves, elbows or other flow disturbances
- Ground the system properly for electrical noise immunity
Usage Notes
- Regularly check sensor mounting tightness and reapply coupling compound as needed
- Ensure pipe wall is clean and free of rust or scale before installation
- For lined pipes, verify lining material compatibility with ultrasonic transmission
- Do not exceed the maximum medium temperature rating of the sensor
- Periodically perform zero flow calibration to maintain measurement accuracy





Reviews
There are no reviews yet.