Description
Technical Specifications
I/O Channels: up to 32, individually configurable as input or output
Digital Input: 24 VDC ±20%, max 4 mA loop current, off current 3 mA
Digital Output: 24 VDC, 1 A short-circuit-proof high-side driver, trip approx. 1.4 A
SPBus Interfaces: 2 redundant interfaces
SPBus Type: RS-485 multidrop
SPBus Isolation: 500 V optocoupler
SPBus Speed: up to 2 MHz, Manchester encoded
Supply: 24 VDC ±20%
Power: max 6 W for inputs; higher for outputs
Dimensions: 355 x 158 x 87 mm
Weight: 1.35 kg
Protection: IP20
Temperature: 0 to 70 °C operating, -25 to 70 °C storage
Standards: IEC 61131-2, IEC 60945, IACS E10
Approvals: DNV, ABS; SIL functions depending on configuration
Functional Features
Individually configurable digital I/O
Dual SPBus for redundancy
Galvanic isolation of bus interface
Line fault detection and earth fault detection
Fail-safe output on communication loss
Self-diagnostics and dual watchdog
DIN-rail mounting with plug-in connections
Status LEDs for operation and faults
Application Scenarios
Marine automation
Ship machinery control
Offshore process systems
Remote valve and relay control
Distributed digital I/O for automation controllers
Working Principle
Field devices connect to screw terminals. The module scans inputs/drives outputs and exchanges data with the controller over SPBus. Redundant bus paths and diagnostics improve availability in critical marine/industrial systems.
Installation Requirements
DIN-rail mount in suitable IP-rated cabinet
Use 24 VDC supply within 19.2 to 28.8 VDC
Terminate and shield SPBus correctly
Separate power and signal wiring where required
Verify SIL/redundancy configuration before commissioning
Usage Notes
Outputs go fail-safe if communication is lost
Check LFD/EFD diagnostics during troubleshooting
Do not exceed 1 A output driver rating
Confirm DNV/ABS scope if used in classed vessels
Perform I/O loop check after installation





Reviews