Product Short Description
Product Introduction:
The Honeywell 1226-9001 is a fixed-mount single-gas toxic gas transmitter designed for continuous area monitoring of specific hazardous gases in industrial environments. It provides a 4–20 mA output with two alarm relays for safety interlock and evacuation signaling. The unit features a catalytic bead or electrochemical sensor depending on gas type.
Description
Technical Specifications:
- Part Number: 1226-9001
- Gas Detected: Carbon Monoxide (CO) — 0–500 ppm range (confirm specific gas variant)
- Sensor Type: Electrochemical (CO-specific)
- Output: 4–20 mA (loop-powered, 2-wire)
- Alarm Relays: 2 SPDT relays — 2 A @ 30 VDC / 250 VAC
- Alarm Setpoints: Low Alarm, High Alarm (programmable)
- Accuracy: ±3 ppm or ±5% of reading (whichever is greater)
- Response Time (T90): < 30 seconds
- Operating Temperature: -40°C to +55°C (-40°F to +131°F)
- Operating Humidity: 0–95% RH (non-condensing)
- Enclosure Rating: NEMA 4X / IP66 (weatherproof)
- Power Supply: 18–30 VDC
- Process Connection: 3/4″ NPT conduit entry (bottom)
- Dimensions: 178 mm × 127 mm × 95 mm
- Weight: 1.2 kg (2.6 lb)
Functional Features:
- Dual alarm relays with independent setpoints
- 4–20 mA output for DCS/PLC integration
- Non-intrusive calibration via magnet or HART
- LED indicators: Power, Alarm 1, Alarm 2, Fault
- Fault relay for sensor failure detection
Performance Parameters:
- Sensor Life: 2 years (CO electrochemical)
- Warm-Up Time: < 60 seconds
- Zero Drift: < ±2 ppm per month
- EMC: EN 61326, FCC Part 15 Class A
- Certifications: UL 2075, CSA C22.2, ATEX Zone 2 (if applicable)
Structural Features:
- UV-stabilized polycarbonate housing
- 3/4″ NPT conduit entry with gland
- Terminal block cover with gasket seal
- Wall-mount bracket included
Working Principle:
CO gas diffuses through a membrane into the electrochemical cell, where it is oxidized at the working electrode, generating a current proportional to gas concentration. The electronics convert this current to a 4–20 mA signal. When concentration exceeds programmable setpoints, the alarm relays activate.
Key Advantages:
- NEMA 4X / IP66 rating for outdoor and corrosive environments
- Dual relays enable staged alarm response (warn + evacuate)
- 2-year sensor life reduces maintenance cost
- HART-compatible for remote configuration
Applicable Industries: Oil and gas, chemical plants, refineries, wastewater treatment, mining, confined space monitoring
Installation Requirements:
- Mount 1.5–3.0 m above floor (CO is near-neutral buoyancy)
- Use shielded twisted-pair cable for 4–20 mA signal
- Loop resistance: 100–600 Ω
- Conduit entry must use provided NPT gland
Usage Notes:
- Bump test sensor monthly with calibration gas
- Full calibration every 6 months or per regulatory requirement
- Replace sensor when “Fault” LED illuminates
- Do not paint or coat the sensor window