Working Principle
- Pressure applied to sensing diaphragm generates proportional strain
- Strain changes resistance in piezoresistive elements
- Signal conditioned to standardized electrical output
Sensor Technology
- Silicon piezoresistive sensing element
- Factory calibration and temperature compensation on supported models
- Wheatstone bridge configuration on strain-gauge designs
Construction Features
- Stainless steel wetted parts on related Honeywell industrial transducers
- All-welded diaphragm options in hazardous-duty families
- Hermetic sealing for harsh media environments
Typical Specifications from Related Honeywell Families
- Output: 4–20 mA two-wire on selected industrial models
- Accuracy: 0.1%, 0.25%, or 0.5% depending on model
- Pressure Type: Gage, absolute, or differential by configuration
- Media: Air, gas, hydraulic fluid, water, and compatible industrial liquids
- Temperature Compensation: Integrated ASIC or passive network
Application Scenarios
- Industrial process control
- Hydraulic and pneumatic systems
- Test and measurement
- Oil and gas equipment
- Harsh-environment pressure monitoring
Installation Requirements
- Confirm pressure range, electrical output, port thread, and connector before use
- Avoid overpressure beyond rated burst limit
- Install according to Honeywell outline drawing and wiring diagram
Usage Notes
- Do not expose sensor to incompatible chemicals
- Verify zero and span after installation
- Protect cable and connector from moisture and mechanical damage