Product Short Description

Product Category: Surface-Mounted Pull Station / Manual Fire Alarm Activation Device


Product Overview:
The Honeywell 05704-A-0146 is a surface-mounted manual fire alarm pull station from the Saf-T-Pop product line. It is a UL-listed, manually activated device designed to trigger a fire alarm system when pulled, providing an immediate notification signal to the connected fire alarm control panel.

Description

Function:
Manual activation of fire alarm notification appliances via pulling the handle or operating the lever, sending a supervised signal to the fire alarm control panel (FACP).


Technical Specifications:

Parameter Specification
Part Number 05704-A-0146
Manufacturer Honeywell International Inc.
Product Line Saf-T-Pop
Type Surface-Mounted Pull Station
Activation Method Pull handle / lever
Contact Rating 1A @ 30VDC (N.O. / N.C. contact)
Supervision End-of-line resistor supervised (1kΩ typical)
Operating Temperature -20°C to 60°C (-4°F to 140°F)
Storage Temperature -40°C to 85°C (-40°F to 185°F)
Relative Humidity 0% to 95% non-condensing
Listing UL Listed, ULC Listed, FM Approved
Compliance NFPA 72, CAN/ULC-S524
Color Red
Housing Material Zinc Die-Cast with Red Powder-Coated Finish
Mounting Type Surface-Mounted
Electrical Connection Screw terminals, 2-wire supervised loop
Dimensions (approx.) 102 mm × 108 mm × 48 mm (4.0 in × 4.3 in × 1.9 in)
Weight (approx.) 0.23 kg (0.5 lb)

Material Composition:

Component Material
Housing Zinc die-cast alloy
Finish Red epoxy powder coat
Internal Contact Silver alloy / gold-plated contacts
Handle / Lever Stainless steel
Mounting Plate Zinc die-cast alloy
Gasket Neoprene rubber (weather seal)
Terminal Blocks Brass / copper alloy

Structural Features:

  • Surface-mounted design with gasketed backplate for weather resistance
  • Red lever-style handle for intuitive manual activation
  • Tamper-resistant reset mechanism requiring a key or special tool
  • Dual N.O./N.C. supervised contact for loop supervision and alarm signaling
  • Pre-wired terminal block for simplified field installation
  • Flush or surface box compatible — mounts to standard 4-inch square electrical box
  • Weatherproof gasket provides IP66 / NEMA 4X rating for outdoor use

Working Principle:

  1. The pull station is connected to the fire alarm control panel via a 2-wire supervised loop with an end-of-line resistor.
  2. Under normal conditions, the circuit is supervised; the FACP continuously monitors loop integrity.
  3. When the red lever is pulled, the internal contacts change state (N.O. closes, N.C. opens), creating an alarm condition.
  4. The FACP detects the change and initiates alarm notification — audible horns, strobes, voice evacuation, etc.
  5. The station must be manually reset using a key or authorized tool after activation.

Key Advantages:

  • UL Listed / FM Approved — meets the highest fire protection standards
  • Surface-mounted with weatherproof gasket — suitable for indoor and outdoor installations
  • Tamper-resistant — prevents unauthorized reset or activation
  • Supervised loop — detects open, short, or ground fault conditions
  • Zinc die-cast housing with powder-coat finish — highly durable, corrosion-resistant
  • Simple 2-wire connection — reduces installation time and wiring errors
  • Compact form factor — low-profile design blends with modern building aesthetics

Applicable Industries:

Industry Application
Commercial Buildings Office towers, shopping malls, retail centers
Industrial Facilities Manufacturing plants, warehouses, refineries
Healthcare Hospitals, clinics, nursing homes
Education Schools, universities, dormitories
Hospitality Hotels, resorts, conference centers
Government / Public Courthouses, airports, transportation hubs
Residential (High-Rise) Apartment complexes, condominiums

Installation Requirements:

  • Mount on a standard 4-inch square electrical box (single-gang or double-gang)
  • Use 18 AWG minimum supervised signaling line cable (SLC) — 2 conductors + shield
  • Maintain maximum loop length per FACP specifications (typically 3,000 ft / 914 m for Class B)
  • Install end-of-line resistor (1kΩ, 1/4W minimum) at the last device on the loop
  • Ensure wire connections are tight at screw terminals — no soldering required
  • For outdoor mounting, verify gasket is properly seated and box is sealed
  • Mounting height: 42 to 48 inches (1067 mm to 1219 mm) from finished floor per NFPA 72 / ADA requirements
  • Keep clear of obstructions — minimum 36 inches (914 mm) of clear space in front

Usage Precautions:

  • Do not cover or paint the pull station — this violates UL listing and may void warranty
  • Do not disconnect the supervised loop without first notifying the fire alarm monitoring company
  • Test monthly per NFPA 72 requirements — pull the handle and verify alarm at the control panel
  • Reset only with authorized key/tool after each activation or test
  • Do not use for non-fire-alarm purposes — false activations are illegal under most fire codes
  • Inspect annually for physical damage, corrosion, or gasket degradation
  • Replace immediately if housing is cracked, contacts are corroded, or gasket is damaged
  • Do not install in areas subject to physical abuse without protective housing or bollards
  • Ensure the FACP zone is properly programmed for this device type (pull station, supervised)

Cross-Reference / Compatible Part Numbers:

Honeywell Part Description
05704-A-0146 Saf-T-Pop Surface-Mount Pull Station — Red
05704-A-0141 Saf-T-Pop Flush-Mount Pull Station — Red
05704-A-0121 Saf-T-Pop Recessed Pull Station — Red
05704-A-0151 Saf-T-Pop Surface-Mount Pull Station — White

Warranty:
Honeywell Saf-T-Pop products carry a limited 5-year warranty from date of manufacture against defects in materials and workmanship under normal use conditions.