This product is an industrial-grade eddy current proximity vibration transmitter manufactured by Bently Nevada (Baker Hughes). It fully matches 3300 NSv series non-contact proximity probes and extension cables. The device converts mechanical radial shaft vibration displacement signals into standard 4–20 mA DC analog current signals proportional to peak-to-peak vibration amplitude. It integrates probe excitation, signal conditioning, amplification, linearization, fault detection and diagnostic signal output functions. Model 990-10-XX-02-00 with modification code 163930-01 adopts bulkhead fixed mounting, supports full-scale range of 0–10 mils peak-to-peak vibration, and is specially customized for OEM rotating machinery vibration monitoring, alarm and control system integration.
Description
Electrical Specifications
- Power Supply: +12 VDC to +35 VDC, 2-wire loop-powered design
- Standard Output Signal: 4–20 mA DC, proportional to peak-to-peak radial vibration displacement
- Full-Scale Measuring Range: 0–10 mils peak-to-peak (0–254 μm peak-to-peak)
- Loop Measurement Accuracy: ±1.5% full scale range (tested at 250 Ω loop resistance)
- Maximum Allowable Loop Resistance: 1000 Ω (including cable resistance, at 35 VDC)
- Typical Current Limiting Value: 23 mA
- Probe Fault Alarm Current: <3.6 mA (Not OK signal for probe disconnection/damage)
- Frequency Response Bandwidth: 5 Hz – 6 kHz (+0 / -3 dB)
- Sensitivity Rating: 7.87 mV/μm
- Temperature Stability: Scale factor variation ≤±10% within 0 °C to +70 °C
- Dynamic Diagnostic Output: Non-isolated PROX OUT & COM terminals + coaxial BNC connector
- Maximum Lead Length to BNC Port: 3 meters
Probe & Mechanical Specifications
- Compatible Probe Model: Bently Nevada 3300 NSv non-contact proximity probe
- System Total Cable Length: XX meters (customizable 5m / 7m / 9m options)
- Effective Working Gap Range: 0.5 mm – 1.75 mm (20–55 mils) between probe tip and metal target
- Minimum Measurable Target Diameter: 9.5 mm
- Mounting Mode: 02 = Bulkhead screw fixed mounting (distinguished from DIN rail mounting)
- External Zero & Span Adjustment: Non-interacting independent potentiometers
- Physical Dimensions: 76.2 mm (H) × 101.6 mm (W) × 50.8 mm (D)
- Transmitter Net Weight: 0.2 kg
Environmental & Construction Specifications
- Transmitter Operating Temperature: -35 °C to +85 °C
- Transmitter Storage Temperature: -52 °C to +100 °C
- Probe Operating Temperature: -52 °C to +177 °C
- Humidity Resistance: 100% condensing environment, non-submerged operation
- Internal Structure: Fully potted sealed circuit, dust-proof, moisture-proof and anti-interference
- Housing Material: Industrial anti-corrosion engineering plastic
Certifications
- CSA/NRTL/C, CE compliance, general industrial safety certification
Core Functional Features
- Integrated Internal Proximitor Sensor Design
No external independent proximitor module required; probe excitation, signal amplification and conditioning are fully integrated inside the transmitter, realizing compact and simplified on-site installation.
- 0–10 mils pp Custom Full-Scale Range (Mod 163930-01)
Special customized measuring range for medium-amplitude rotating machinery vibration monitoring, matching OEM system alarm threshold settings.
- Bulkhead Fixed Mounting Structure (02 Code Configuration)
Adopts panel/bulkhead screw mounting instead of DIN rail, suitable for machinery local control box and compact equipment internal installation.
- Independent Non-Interacting Zero & Span Calibration
External adjustable zero and span potentiometers under label cover, realizing accurate loop current calibration without mutual interference.
- Built-In Test Input Interface
Supports function generator signal injection, realizing fast loop output verification and on-site debugging without dismounting equipment.
- Complete Not OK Fault Protection Circuit
Automatically detects probe damage, cable breakage and loose connection faults; outputs <3.6 mA low-current alarm signal to completely avoid false high-vibration alarms.
- Power-On Startup Inhibit Function
Blocks abnormal transient signals during power-on startup to prevent system false alarm actions.
- Dual Signal Output Architecture
Primary output: 4–20 mA analog signal for PLC/DCS control and alarm; Secondary output: dynamic vibration + gap voltage analog signal for advanced machinery fault diagnosis and analysis.
- High Reliability Sealed Packaging
Fully potted internal circuit, resistant to dust, moisture and strong electromagnetic interference in harsh industrial sites.
Application Scenarios
- Centrifugal air compressors & gas compressors
- Industrial oil pumps, water pumps and pipeline pumps
- High-voltage induction motors & high-speed rotating motors
- Industrial fans, blowers and exhaust equipment
- Petrochemical processing rotating machinery
- Oil & gas field production rotating equipment
- Power plant auxiliary rotating machinery
- Wastewater treatment rotating equipment
- Machinery predictive maintenance & health management systems