Product Short Description
Product Introduction
The Bently Nevada 9200-06-05-10-00 is a two-wire velocity transducer that forms part of the Seismoprobe family of moving-coil vibration sensors. It is engineered to measure absolute vibration of bearing housings, casings, or structures relative to free space. The 9200 series is suitable for continuous condition monitoring as well as periodic measurement in conjunction with test and diagnostic instruments.
Description
Technical Specifications
-
Sensitivity: 20 mV/mm/s (500 mV/in/s), ±5% at proper termination and calibration angle
-
Frequency Response: 10 Hz to 1000 Hz (600 to 60,000 CPM), +0/−3 dB typical
-
Mounting Configuration: Top mount with M10×1 stud (Option 06 = 0°±100° orientation)
-
Cable Length: Up to 305 m (1000 ft) between transducer and monitor
-
Operating & Storage Temperature: −29 °C to +121 °C
-
Dimensions: 41 mm diameter × 102 mm height
-
Weight: 480 g typical
-
Shock Resistance: 50 g peak maximum acceleration
-
Transverse Sensitivity: Maximum ±10%
Functional Features
-
Moving-coil technology delivers a voltage output directly proportional to vibration velocity.
-
Less sensitive to impact or impulsive excitation compared with solid-state velocity transducers.
-
No external power required, making it ideal for portable measurement.
-
Excellent corrosion resistance when ordered with integral cable option, with no additional protection needed.
-
Matches Bently Nevada 3500/42, 1900/65, and 2300/20 monitoring systems.
Application Scenarios
Deployed in power generation, steel, chemical, petrochemical, and metallurgy industries for vibration monitoring of turbines, compressors, pumps, fans, gearboxes, and reciprocating compressors.
Working Principle
The 9200 transducer employs a moving-coil mechanism: as the transducer vibrates, the coil moves within a magnetic field, inducing a voltage proportional to vibration velocity. This voltage signal is transmitted via a two-wire system to a monitoring device.
Installation Requirements
-
Install using the M10×1 stud with top-mount orientation.
-
Use only recommended interconnect cables: 9571 (shielded, 22 AWG) or 84661 (armored, 22 AWG).
-
Maximum cable run is 305 m; longer runs may introduce frequency attenuation.
-
For temporary mounting, accessory 46000-01 magnetic base can be used.
Usage Precautions
-
Avoid exposing the transducer beyond its shock rating of 50 g peak.
-
Ensure proper orientation during calibration to maintain stated sensitivity tolerance.
-
Do not operate outside the specified temperature range of −29 °C to +121 °C.
-
Verify cable integrity periodically to prevent signal degradation.





Reviews