Product Short Description

Product Name: ALC12DE-010-1312
Type: Power Electronics / Traction Converter Module
Manufacturer: Alstom Transport
Series: ALC12DE Series

Description

Product Description:
The ALC12DE-010-1312 is a traction converter module (inverter) from Alstom’s ALC12DE product family. It converts DC link power from the overhead catenary or third rail into controlled three-phase AC power for driving Alstom traction motors. This unit is used in modern EMUs and locomotives with Alstom ONIX or AGATE control platforms.

Technical Specifications:

  • Type: 2-level Voltage Source Inverter (VSI)
  • Rated Input Voltage: 750 VDC to 1,800 VDC (adjustable)
  • Rated Output Power: 1,200 kW (continuous per module)
  • Output Frequency: 0 to 300 Hz
  • Switching Technology: IGBT modules (6500V / 1200A class)
  • Cooling Method: Water-cooled heat sink (ethylene glycol loop)
  • Efficiency: >98% at rated load
  • Weight: Approximately 420 kg
  • Protection Rating: IP54 (with enclosure)

Construction & Materials:

  • Power Semiconductors: IGBT modules (Infineon or Mitsubishi)
  • DC Link Capacitors: Film capacitors, 1,800 VDC rated
  • Heat Sink: Extruded aluminum with micro-channel water cooling
  • Control Board: Alstom proprietary DSP-based controller (AGATE)
  • Enclosure: Powder-coated steel, EMC shielded

Key Features:

  • Regenerative braking capability (energy fed back to catenary)
  • Advanced vector control (FOC) for precise torque control
  • Built-in diagnostic and fault logging (Alstom HealthHub compatible)
  • Modular design allows hot-swap replacement
  • EMC compliant: EN 50121-3-2

Applicable Industries:

  • Electric multiple units (EMU)
  • Electric locomotives
  • Metro and tram systems
  • Hybrid rail vehicles

Installation Requirements:

  • Mount in converter cabinet with minimum 200 mm clearance on all sides
  • Water cooling loop: flow rate 8 L/min, inlet temp 25°C ±5°C
  • DC bus connections: torque 80 Nm on M10 terminals
  • Ground connection: < 0.1 Ω to chassis ground

Usage Notes:

  • Perform coolant quality check quarterly (glycol concentration 40-50%)
  • IGBT module temperature must not exceed 125°C
  • Filter capacitors must be discharged before servicing (wait 5 minutes after power-off)