Product Short Description
The ABB SPAJ110C is a non-directional, microprocessor-controlled earth-fault protection relay, belonging to ABB’s SPACOM product family and designed for medium-voltage power distribution systemsABB Group. It provides selective earth-fault protection, functioning as primary or backup protection in solidly earthed or low-resistance earthed power networksABB Group. Engineered with a modular hardware design and advanced digital signal processing, it delivers precise zero-sequence (residual) current monitoring and protection. It integrates comprehensive measurement, protection, control, and communication functions, serving as a critical component for ensuring safe and stable operation in power distribution systems.
Description
Technical Specifications
- Product Type
- Non-directional earth-fault protection relay (secondary relay)
- Protected System
- Applicable System: Solidly earthed or low-resistance earthed power systemsABB Group
- Rated Frequency: 50 Hz / 60 Hz
- Current Input
- Rated Current (In): 1 A or 5 A (configurable)
- Low-set Stage (I₀>): 0.1 ~ 0.8 × In
- High-set Stage (I₀>>): 0.1 ~ 4.0 × In (or disabled)
- Thermal Withstand: 4 A continuous (1 A In) / 20 A continuous (5 A In)
- Dynamic Withstand: 250 A (1 A In) / 1250 A (5 A In)
- Time Characteristics
- Low-set Stage: Definite time (0.05 ~ 100 s) or Inverse Time (IDMT)
- Inverse Time Curves: Normal inverse, Very inverse, Extremely inverse, Long-time inverse (per IEC 60255-4, BS 142)
- High-set Stage: Definite time (0.05 ~ 100 s)
- Operating Time Accuracy: ±2% of set value or ±25 ms
- Auxiliary Power Supply
- SPTU 240S1: 80 ~ 265 V AC/DC
- SPTU 48S1: 18 ~ 80 V DC
- Power Consumption: Approx. 4 W (standby), 6 W (operating)
- Output Contacts
- Trip Contacts: 250 V AC/DC, 5 A continuous, 30 A for 0.5 s
- Signal Contacts: 250 V AC/DC, 5 A continuous
- Quantity: 3 ~ 4 configurable relay outputs
- Physical & Mechanical Data
- Dimensions: 170 mm (H) × 100 mm (W) × 85 mm (D)
- Weight: Approx. 1.2 kg
- Mounting: Panel mounting (flush/semi-flush)
- Protection Class: IP54 (front), IP20 (rear)
- Environmental Ratings
- Operating Temperature: -10 °C to +55 °C
- Storage Temperature: -40 °C to +85 °C
- Relative Humidity: 5 – 95% RH (Non-condensing)
- Vibration/Shock: Complies with IEC 61131-2
- Compliance & Certifications
- Standards: IEC 60255, IEC 61000-6-2, IEC 61000-6-4
- Certifications: CE, UL, cUL
Key Features
- Dual-Stage Earth-Fault Protection
- Independent Dual Stages: Integrates low-set (I₀>) and high-set (I₀>>) protection stages for comprehensive fault coverageABB Group.
- Flexible Time Curves: Low-set stage supports both definite-time and four selectable inverse-time characteristics for optimal coordination.
- High-Set Instantaneous: High-set stage provides fast, definite-time clearance for severe fault conditionsABB Group.
- Wide Setting Ranges: Extensive current and time settings ensure adaptability to diverse system conditions.
- Advanced Measurement & Monitoring
- Precise Sensing: Accurately measures zero-sequence current via residual connection or core-balance CT.
- Digital Display: Front-panel digital display for real-time parameters, settings, and fault data.
- Fault Recording: Logs fault values, operating times, and event codes for post-fault analysis.
- Continuous Sampling: High-speed signal sampling ensures fast and accurate fault detection.
- Self-Supervision & Diagnostics
- Built-in Self-Test: Continuous hardware and software self-supervision with auto-diagnosticsABB Group.
- Fault Alarm: Triggers internal alarm and indicates faults via front-panel LEDs upon detecting internal failures.
- Event Logging: Stores and reports detailed event codes for system and relay diagnostics.
- High Reliability: Minimizes relay failure risk and supports predictive maintenance.
- Flexible Configuration & Integration
- Configurable Outputs: Output relay functions are freely configurable to meet specific application logicABB Group.
- External Blocking: Supports blocking/deblocking via external residual voltage relays or remote signals.
- Serial Communication: Equipped with a serial port for connection to fiber-optic SPA-bus and SCADA systems.
- System Compatibility: Fully compatible with ABB’s Distribution Automation systemsABB Group.
- Robust Industrial Design
- Conformal Coating: PCB protected against dust, humidity, and corrosive industrial atmospheres.
- EMC Immunity: High immunity to electromagnetic interference per IEC 61000 standards.
- Wide Temperature Range: Stable operation across extreme industrial temperature variations.
- Long Service Life: Industrial-grade components ensure reliable long-term operation.
Application Scenarios
- Power Distribution Networks
- Feeder Lines: Primary/backup earth-fault protection for outgoing feeders in distribution substationsABB Group.
- Distribution Transformers: Protects distribution transformers against winding earth faultsABB Group.
- Ring Main Units (RMUs): Integrated protection for compact secondary distribution systemsABB Group.
- Cable Networks: Reliable earth-fault detection for underground power cable systemsABB Group.
- Industrial Power Systems
- Large Motors: Earth-fault protection for high-voltage industrial motorsABB Group.
- Generators: Backup earth-fault protection for synchronous and asynchronous generatorsABB Group.
- MCCs: Protection for motor control centers in manufacturing plants.
- Auxiliary Systems: Protects auxiliary transformers and drives in power plantsABB Group.
- Mining & Metals Industry
- Mine Power Supply: Protection for underground and surface mine distribution networks.
- Smelting Plants: Reliable operation in high-temperature, high-dust metallurgical environments.
- Rolling Mills: Protects drive systems and auxiliary power suppliesABB Group.
- Oil & Gas Industry
- Onshore/Offshore Platforms: Earth-fault protection for drilling and processing equipment.
- Pumping Stations: Protects long-distance pipeline pump motors.
- Refineries: Safe operation in hazardous and corrosive process areas.
- Water & Wastewater Treatment
- Pump Stations: Protects large water supply and drainage pump motors.
- Treatment Plants: Reliable protection for process equipment and distribution systems.
- Marine & Offshore
- Shipboard Power: Earth-fault protection for marine electrical distribution systems.
- FPSO Vessels: Robust performance under marine vibration and humidity conditions.





Reviews