Product Short Description
The ABB REX521GHHPSH07G is a sophisticated, microprocessor-based digital protection and control device. It delivers complete protection, measurement, control, and supervision functions for medium-voltage power distribution networks and medium-to-large size three-phase AC motors. This unit integrates advanced protection algorithms, precise monitoring, and flexible communication capabilities in a compact, robust package. It supports standard configurations for multiple network types and serves as a primary protection solution for feeders and motors, while also providing reliable backup protection for transformers and high-voltage lines. It is purpose-built for stable operation in single-busbar substation arrangements.
Description
Technical Specifications
Power Supply
- Auxiliary Voltage: 100–240 V AC/DC (±15% tolerance), wide-range input
- Frequency: 50/60 Hz (dual-frequency compatible)
- Power Consumption: 10 W (typical)
Analog Inputs
- Current Inputs: 3×phase current inputs (1 A or 5 A nominal CTs), 1×residual current input
- Voltage Inputs: 3×phase voltage inputs (100–120 V nominal VTs), 1×residual voltage input
- Sensor Compatibility: Supports conventional CT/VT and non-conventional current/voltage sensors
- Input Isolation: 2500 V rms galvanic isolation between all analog inputs
Digital Inputs/Outputs
- Digital Inputs: 16×optically isolated binary inputs (24–250 V DC/AC)
- Trip Outputs: 4×high-speed relay outputs (changeover contacts) for fault tripping
- Control Outputs: 8×general-purpose relay outputs for signaling and control
- Contact Rating: 5 A at 250 V AC / 30 V DC (resistive load)
Communication Interfaces
- Serial Ports: 2×RS-485 ports (galvanically isolated)
- Supported Protocols: Modbus RTU, DNP3.0, SPA communication protocols
- Optical Ports: Optional fiber-optic ports for noise-immune long-distance communication
- Time Synchronization: IRIG-B, SNTP network time synchronization
Display & HMI
- Display: 128×64 pixel monochrome LCD with backlight
- Controls: 8×front-panel pushbuttons for local operation and configuration
- Indicators: 12×LED indicators for power, operation, fault, and alarm status
- Interface: Local parameter setting, fault data viewing, and operation log access
Physical & Environmental
- Mounting: Panel-mounted (144 mm × 144 mm standard cut-out)
- Dimensions: 144 mm (W) × 155 mm (H) × 120 mm (D)
- Weight: 1.8 kg (approximate)
- Operating Temperature: -25°C to +70°C
- Storage Temperature: -40°C to +85°C
- Humidity: 5–95% non-condensing
- Protection Rating: Front panel IP40, rear IP20
- Certifications: IEC 60255, IEC 61850 (via adapter), CE, UL, EMC compliant
Performance
- Sampling Rate: 1.6 kHz per channel
- Trip Time: <30 ms (overcurrent protection)
- Fault Recording: 8×analog channels, 16×binary channels
- Event Logging: 500+ time-stamped events with 1 ms resolution
- Measurement Accuracy: Current/voltage: ±0.2%, power/energy: ±0.5%
Key Functional Features
Comprehensive Feeder Protection
- Overcurrent Protection: Three-stage phase overcurrent (50/51) with definite and inverse time characteristics
- Earth Fault Protection: Sensitive residual overcurrent (50N/51N), directional earth fault (67N)
- Voltage Protection: Two-stage overvoltage (59), two-stage undervoltage (27), residual overvoltage (59G)
- Frequency Protection: Overfrequency (81O), underfrequency (81U), frequency rate-of-change protection
- Automatic Reclosing: Up to 5-shot auto-reclose with programmable dead time and reclaim time
- Fuse Failure Protection: Detects blown VT fuses and blocks voltage-dependent functions
Advanced Motor Protection
- Thermal Overload Protection: Precise thermal model for stator and rotor windings (49)
- Start-Up Supervision: Monitors motor start time, locked rotor condition, and start attempt limits
- Stall Protection: Detects motor stall during operation and initiates rapid tripping
- Phase Unbalance Protection: Detects negative-sequence current and phase loss conditions
- Reverse Phase Protection: Prevents motor operation with incorrect phase sequence
- Underload Protection: Detects broken belts or uncoupled loads (motor dry-running)
Control & Automation
- Local/Remote Control: Circuit breaker trip/close control with local/remote selection
- Interlocking Logic: Programmable logic for safety interlocks and operational sequences
- Setting Groups: 4×configurable setting groups for flexible operational mode switching
- Sequence of Events: Captures breaker operations and fault events with high time resolution
Measurement & Monitoring
- Precision Metering: True RMS measurement of current, voltage, power (active/reactive/apparent), energy, power factor, frequency
- Continuous Supervision: Trip circuit supervision, breaker wear monitoring, CT/VT integrity check
- Self-Diagnostics: Continuous hardware/software monitoring with pre-alarm and fault indication
- Oscillography: Fault waveform recording for post-incident analysis
System Integration
- Multi-Protocol Support: Seamless integration with SCADA and substation automation systems
- Legacy Compatibility: Works with existing control systems via standard serial protocols
- Remote Access: Parameter setting, fault analysis, and status monitoring via communication network
- Configuration Tools: PC-based software for parameter configuration, logic programming, and diagnostics
Application Scenarios
Medium-Voltage Distribution Networks
- Distribution Substations: Primary protection for incoming and outgoing feeders
- Radial Networks: Protection for radial isolated neutral, resonant earthed, and resistively earthed systems
- Single Busbar Systems: Main protection for feeders in compact substation layouts
- Urban/Rural Grids: Feeder protection in municipal and rural power distribution networks
Industrial Motor Control
- Pumps & Fans: Protection for large water pumps, ventilation fans, and centrifugal compressors
- Conveyors & Mills: Motor protection for mining conveyors, grinding mills, and material handling systems
- Compressors & Blowers: Protection for industrial air compressors and process blowers
- Manufacturing Lines: Motor feeders in automotive, textile, and general manufacturing plants
Power Generation Plants
- Auxiliary Systems: Protection for generator auxiliary motors and plant feeders
- Cogeneration Plants: Medium-voltage feeder and motor protection in combined heat and power plants
- Renewable Plants: Collector feeder protection in solar and wind power facilities
Oil & Gas Industry
- Refineries: Motor protection for pumps, compressors, and process drive motors
- Offshore Platforms: Feeders and motor protection in marine and offshore applications
- Pipelines: Compressor station motor and distribution feeder protection
Water & Wastewater
- Water Treatment: Protection for pump motors and process feeders
- Wastewater Plants: Aeration blower and sludge pump motor protection
- Irrigation Systems: Large pump station feeder and motor protection
Mining & Minerals
- Mineral Processing: Crusher, mill, and conveyor motor protection
- Open-Pit Mining: Shovel, dragline, and pumping system motor protection
- Underground Mining: Flameproof-compatible feeder and motor protection
Marine & Offshore
- Shipboard Systems: Marine-certified protection for main and auxiliary motors
- Offshore Vessels: Feeders and thruster motor protection in dynamic positioning systems
- Naval Applications: Military vessel medium-voltage motor and feeder protection





Reviews
There are no reviews yet.