Product Short Description
The ABB REX521GHHGSH05G is a high-performance, multi-functional numerical protection and control relay belonging to the ABB REX 521 series. It is engineered for comprehensive protection, control, measurement, and supervision in medium-voltage (MV) power distribution networks and for safeguarding large and medium-sized three-phase AC motors. This device integrates advanced protection algorithms, precision measurement, robust logic control, and versatile communication capabilities into a compact, industrial-grade unit. It supports standard pre-configurations and is adaptable to various network earthing systems, serving as a reliable solution for feeder bays, motor bays, and substation backup protection in modern power systems.
Description
Technical Specifications
- Product Type
- Numerical Feeder and Motor Protection & Control Relay
- Application Voltage Level
- Medium Voltage (MV): 6 kV – 36 kV
- Auxiliary Power Supply
- AC: 110/120/220/240 V AC, ±15%, 50/60 Hz
- DC: 110/125/220 V DC, ±20%
- Analog Inputs
- Phase Current Inputs: 3 channels, configurable for 1 A or 5 A nominal CT secondary
- Residual Current Input: 1 channel (5 A / 1 A)
- Voltage Inputs: 3-phase voltage + 1 residual voltage input
- Sensor Compatibility: Supports conventional current/voltage transformers and electronic sensors
- Binary Inputs/Outputs
- Binary Inputs: 16 optically isolated, programmable digital inputs
- Binary Outputs: 10 relay outputs (4 power outputs, 6 signal outputs)
- Communication Interfaces
- Serial: RS-485 port
- Local: Front USB port for configuration and service
- Optional: Ethernet port for network communication
- Supported Communication Protocols
- Modbus RTU/TCP
- DNP3.0
- SPA Bus
- IEC 60870-5-103
- Optional IEC 61850
- Physical Characteristics
- Mounting: 19-inch rack-mountable, compact design
- Display: Backlit graphical LCD with multi-language support
- Control: Front-panel navigation buttons and LED status indicators
- Protection Class: IP20 (front and rear)
- Environmental Ratings
- Operating Temperature: -25 °C to +55 °C
- Storage Temperature: -40 °C to +70 °C
- Humidity: 5 – 95% RH (non-condensing)
- EMC Compliance: IEC 60255-6, EN 55011
- Certifications
- CE, UL, IEC 60255
Key Features
- Comprehensive Protection Functions
- Overcurrent Protection: Three-stage, directional/non-directional phase and residual overcurrent protection with definite time (DT) and inverse definite minimum time (IDMT) characteristics.
- Earth Fault Protection: Sensitive earth-fault (SEF) and directional earth-fault protection for high-impedance fault detection.
- Voltage & Frequency Protection: Overvoltage, undervoltage, residual overvoltage, phase imbalance, phase reversal, and over/under frequency protection.
- Motor-Specific Protection: Thermal overload, stall protection, start-up supervision, phase discontinuity, and fuse failure detection.
- Advanced Functions: Circuit breaker failure protection (CBFP), trip circuit supervision, thermal overload for cables, and harmonic restraint for transformer inrush detection.
- Auto-Reclose: Multi-shot automatic reclosing (up to 5 cycles) with configurable dead time and reclaim time.
- Precision Measurement & Monitoring
- Real-time measurement of three-phase current/voltage, power, energy, power factor, and frequency with high accuracy.
- Power quality monitoring: Total Harmonic Distortion (THD) analysis for current and voltage.
- Event Recording: Stores over 1000 time-stamped events (Sequence of Events – SOE).
- Disturbance Recorder: Captures fault data in COMTRADE format for post-fault analysis.
- Circuit breaker monitoring: Tracks mechanical wear, operation count, and coil performance.
- Programmable Logic & Control
- Embedded customizable logic control for automation, interlocking, and control schemes.
- Local and remote circuit breaker control.
- Configurable input/output logic for flexible system integration.
- Operational Flexibility & Security
- Pre-defined standard configurations (B01/B02/M01/M02/H-series) for rapid deployment.
- Multi-setting group functionality for adaptive operation under varying conditions.
- Password-protected settings and role-based user authentication to prevent unauthorized access.
- Continuous self-diagnostics and internal fault monitoring for high availability.
- Seamless System Integration
- Wide protocol support ensures compatibility with SCADA, DCS, and substation automation systems.
- Facilitates easy retrofitting into existing switchgear and control systems.
- Supports remote configuration, monitoring, and firmware updates.
Application Scenarios
- Medium Voltage Utility Distribution
- Primary protection for overhead lines and underground cables in radial and looped networks.
- Incoming and outgoing feeder protection in distribution substations and ring main units (RMUs).
- Suitable for isolated neutral, resonant earthed, solidly earthed, and resistively earthed systems.
- Industrial Power Systems
- Protection and control for large medium-voltage motors (pumps, fans, compressors, mills).
- Motor control center (MCC) protection in manufacturing, mining, and processing plants.
- Critical load protection in petrochemical, water treatment, and cement factories.
- Substation Automation
- Acts as a bay controller for feeder and motor bays.
- Provides backup protection for power transformers and high-voltage lines.
- Integrates into legacy and modern substation automation systems.
- Commercial & Infrastructure
- MV distribution protection in data centers, airports, seaports, and large commercial buildings.
- Ensures reliable power supply for critical infrastructure and continuous production processes.
- Grid Modernization
- Deployed in smart distribution grids for fault location, isolation, and service restoration (FLISR).
- Enables remote monitoring and control for efficient grid operation and maintenance.






Reviews