Product Short Description

Product Overview
The 3BHB020945R0010 is an auxiliary contactor, Eaton/Moeller type DILA-XHI11, supplied by ABB as a spare part for the ACS 6000 medium-voltage drive and related converter panels. ABB spare-part lists pair it with its sibling 3BHB020945R0001 (DILA-22, 24 VDC) as the auxiliary-contact components used on the drive cabinets.

Description

Technical Specifications
Device type: auxiliary contactor, DILA-XHI11 configuration. Contact configuration 1 NO + 1 NC. Control voltage 24 VDC (matching the ACS6000 panel auxiliary supply). Product net weight 0.04 kg, supplied as one piece per package. Mounting on standard auxiliary-contactor base or direct to the main contactor in the cabinet.
Functional Features
One normally open and one normally closed auxiliary contact for signaling and interlocking circuits; compact 24 VDC coil with low holding power; force-guided contact mechanism ensuring reliable switching of the control signals used in the drive’s auxiliary circuits.
Applications
Auxiliary switching and interlocking in ABB ACS 6000 drive control cabinets; general auxiliary-contact duty in industrial control panels where a DILA-XHI11 24 VDC device is specified.
Material Composition
Relay mechanism with silver-alloy contacts in a thermoplastic housing; 24 VDC electromagnetic coil with integrated suppression; plug-in connection terminals for the control wiring.
Structure and Characteristics
Compact modular auxiliary contactor designed for front mounting on contactors or base mounting on DIN rail; the XHI11 code identifies the 1 NO + 1 NC contact arrangement in the DIL series housing.
Working Principle
The 24 VDC control voltage energizes the coil and moves the contact mechanism, switching the NO contact closed and the NC contact open. Through these contacts the drive’s auxiliary circuits signal contactor state, drive enables, door interlocks and similar binary statuses to the control system.
Installation Requirements
Isolate the control supply before replacement, record the terminal wiring, fit the replacement with identical contact orientation, restore the wiring to the documented terminals, and function-test both the NO and NC circuits before returning the cabinet to service.
Precautions
Verify the coil voltage (24 VDC) and the contact code (XHI11 = 1 NO + 1 NC) before ordering, since neighboring order numbers cover different configurations such as DILA-22 (3BHB020945R0001) or auxiliary blocks like NHI11-PKZO.