Product Short Description

Product Name:​ Woodward 9907-1200 MicroNet TMR / MicroNet Plus I/O Speed-Control Interface Module
Product Introduction:​ A high-integrity I/O and speed-sensing interface module for Woodward MicroNet TMR or MicroNet Plus turbine/engine controllers. Acts as the conditioned bridge between magnetic pickups, RTD/mA field signals and the central 19″ rack CPU.

Description

Technical Specifications:
  • Form factor: 19″ rack / MicroNet Plus backplane module (3U class), IP20
  • Speed inputs: 2 independent channels, magnetic pickup or TTL, up to 10 kHz (some listings 1 MHz for encoder option)
  • Analog inputs: 8 channels configurable 4–20 mA / 0–10 V / RTD Pt100
  • Analog outputs: 4 channels 4–20 mA, isolated 12-bit
  • Control output: 4–20 mA to electro-hydraulic valve / actuator (500 Ω load)
  • Communication: MicroNet backplane UBUS, 100Base-TX Ethernet, CANopen (Rev D)
  • Redundancy: hot-swap, dual-module TMR support
  • Supply: via backplane +5 V / ±15 V DC
  • Operating temp: -20 °C to +70 °C
  • Isolation: 500 V RMS field/logic
Functional Features:​ Dual cross-checked speed channels for overspeed validation; software-selectable I/O (no jumpers); deterministic < 1 ms scan; TMR voting ready; CE/UL/ATEX options.
Application Scenarios:​ Gas turbine speed/load control, steam turbine governing, reciprocating-engine generator sets, marine propulsion, oil & gas compressor trains.
Working Principle:​ Magnetic pickup frequency converted to rpm; analog inputs digitised and passed over backplane to MicroNet CPU; CPU executes speed/load algorithm and writes 4–20 mA outputs back through module to servo valves.
Installation Requirements:​ Seated in MicroNet Plus chassis with keyed slot; backplane grounding continuity; shielded twisted pair for magnetic pickup; separate field wiring compartment; DIN/rack earthing to plant ground.
Usage Notes:​ Never mix 115 V field wiring with RTD inputs; redundant module swap only with CPU in run-permit state; verify speed pickup gap and teeth count in Toolkit before start; do not expose field side to > 500 V.

Reviews

There are no reviews yet.

Be the first to review “Woodward 9907-1200”

Your email address will not be published. Required fields are marked *

View Related Products