Product Short Description
Product Name: ProSoft 3100-MCM Modbus Communication Module for PLC-5
Product Introduction:
The ProSoft 3100-MCM is a Modbus Master/Slave communication module developed for Allen-Bradley PLC-5 processors. It enables Rockwell Automation PLC systems to communicate directly with Modbus-compatible devices including drives, analyzers, meters, and third-party control equipment, extending the life of legacy PLC-5 installations.
Description
Technical Specifications:
-
Manufacturer: ProSoft Technology
-
Compatible Controllers: Allen-Bradley PLC-5
-
Module Type: Modbus communication interface
-
Supported Protocols: Modbus RTU, Modbus ASCII
-
Operating Modes: Master or Slave (independent per port)
-
Communication Ports: 2 × DB-25 female
-
Electrical Standards: RS-232, RS-422, RS-485 (configurable)
-
Baud Rate Range: 300 to 19.2 kbps
-
Data Format: 8 data bits, selectable parity, 1 stop bit
-
Maximum Nodes: Up to 32 nodes per RS-485 segment
-
Power Supply: 5 VDC from PLC backplane
-
Operating Temperature: 0 °C to +60 °C
-
Storage Temperature: -40 °C to +85 °C
-
Humidity: 5–95% non-condensing
-
Lifecycle Status: Discontinued / legacy product
Functional Features:
-
Dual independent ports allow simultaneous Master and Slave operation
-
Supports both Modbus RTU and Modbus ASCII protocols
-
Configurable via DIP switches and ProSoft configuration tools
-
Draws power directly from the PLC-5 backplane — no external supply needed
-
LED indicators provide module and communication status
-
Bridges legacy PLC-5 systems with modern Modbus field devices
Application Scenarios:
-
Integration of Modbus RTU/ASCII field devices into existing PLC-5 systems
-
Process automation requiring connectivity to Modbus drives and analyzers
-
Utility systems linking meters and third-party controls to PLC-5
-
Legacy system modernization without replacing the core controller
Installation Requirements:
-
Insert directly into a PLC-5 chassis slot
-
Verify backplane power supply has sufficient headroom for the module draw
-
Configure DIP switches for baud rate, parity, and node address
-
Use high-quality shielded twisted-pair cabling for RS-485 networks
-
RS-232 cable runs limited to approximately 15 meters; RS-485 extends to 1200 meters
Usage Notes:
-
Port 1 can be set as Master while Port 2 acts as Slave, or any combination thereof
-
Proper termination resistors are required on RS-485 multi-drop networks
-
As a discontinued product, source from authorized surplus suppliers with warranty
-
Configure using ProSoft configuration tools for precise protocol behavior