Product Short Description
Product Overview:
The Woodward 9907-028 is a protocol gateway module designed for high-speed, real-time data exchange between Woodward EasyGen governors and third-party SCADA, DCS, PLC, and HMI systems. It translates Woodward proprietary W-Net serial protocol (RS-485) into Modbus RTU (serial) and Modbus TCP/IP (Ethernet) simultaneously, enabling seamless integration with virtually any industrial automation platform without requiring custom software development.
Description
Product Category: Protocol Gateway / Serial-to-Ethernet Converter
Function: Bidirectional protocol translation — W-Net ↔ Modbus RTU ↔ Modbus TCP/IP
Communication Interfaces:
- Port 1 (Governor Side): RS-485, W-Net proprietary protocol, 4-wire shielded twisted pair, 9600–115200 baud
- Port 2 (Serial Side): RS-485, Modbus RTU, 4-wire shielded twisted pair, 9600–115200 baud
- Port 3 (Ethernet Side): 10/100 Base-TX, RJ-45, Modbus TCP/IP server and client
Supported Protocols: W-Net (Woodward proprietary), Modbus RTU (Master/Slave), Modbus TCP/IP (Server/Client)
Data Points Supported: Governor speed, load, fuel valve position, temperature, pressure, alarm status, operating mode, setpoints, event logs, diagnostics
Data Update Rate (Serial): Configurable from 100 ms to 2000 ms (default 250 ms)
Data Update Rate (Ethernet): Configurable from 100 ms to 5000 ms (default 500 ms)
Maximum Simultaneous Modbus TCP/IP Clients: 8 connections
Modbus Register Range: Holding registers 40001–49999, Coils 00001–09999, Discrete Inputs 10001–19999, Input Registers 30001–39999
Baud Rate Options: 9600, 19200, 38400, 57600, 115200 bps (configurable per port)
Response Time (Serial): Less than 20 ms (typical)
Response Time (Ethernet): Less than 50 ms (typical)
Packet Size (Modbus TCP/IP): Up to 1024 bytes per transaction
Operating Temperature Range: 0°C to +60°C (32°F to +140°F)
Storage Temperature Range: -40°C to +85°C (-40°F to +185°F)
Ambient Humidity: 5% to 95% RH, non-condensing
Altitude: Up to 3000 m (9842 ft) above sea level
Vibration: 5 g, 10–500 Hz (operating); 10 g, 10–500 Hz (survival)
Shock: 30 g, 11 ms half-sine
Ingress Protection: IP20 (indoor use only, panel-mounted)
EMC Compliance: EN 61000-6-2 (industrial environment), EN 61000-6-4 (emission)
Housing Material: ABS plastic (UL 94 V-0 rated) — flame retardant
Front Panel: Polycarbonate lens with 5 LED status indicators
PCB Material: FR-4, conformal coated
Connector (Ethernet): RJ-45, gold-plated contacts, shielded, with integrated magnetics
Connector (Serial Port 1): RJ-45, 8P8C, shielded, W-Net to governor
Connector (Serial Port 2): RJ-45, 8P8C, shielded, Modbus RTU to SCADA/PLC
Terminal Block (Power): Screw-clamp, tin-plated brass, 2 positions (24 VDC input)
Grounding Terminal: Dedicated earth terminal, green/yellow, 4 mm² minimum wire size
Mounting: DIN rail (35 mm, EN 60715) or panel mount with bracket
Dimensions (approximate): 120 mm × 95 mm × 35 mm (W × H × D)
Weight: Approximately 0.35 kg (0.77 lbs)
Structure:
- Compact rectangular enclosure with DIN rail mounting clips on top and bottom
- Front panel: 5 LED status indicators (Power ON, Ethernet Link, Serial 1 Active, Serial 2 Active, Fault/Alarm)
- Rear panel: 1 × RJ-45 Ethernet port, 2 × RJ-45 serial ports (Port 1: W-Net, Port 2: Modbus RTU), 1 × 2-pin screw-clamp terminal block (24 VDC power)
- Internal: Single multilayer PCB with dual RS-485 transceivers, Ethernet PHY with integrated magnetics, microprocessor (ARM Cortex-M4), 256 KB Flash, 64 KB RAM, isolation transformers (2×), and voltage regulator
- Labeling: Model number, serial number, IP address, MAC address, W-Net node address printed on rear label
Working Principle:
The 9907-028 contains a dual-port RS-485 interface and an Ethernet interface connected by an internal ARM Cortex-M4 microprocessor. On Port 1 (W-Net side), the module communicates with the Woodward EasyGen governor using the W-Net proprietary protocol over RS-485. The microprocessor continuously polls the governor for real-time data (speed, load, valve position, alarms) at the configured update rate (default 250 ms) and stores the data in an internal circular buffer (64 KB RAM). On Port 2 (Modbus RTU side), the module acts as a Modbus RTU slave, responding to read/write requests from a SCADA or PLC over RS-485. The microprocessor translates Modbus RTU register addresses into internal W-Net data points, reads the value from the buffer, and returns it in Modbus format. On Port 3 (Ethernet side), the module acts as a Modbus TCP/IP server, listening for TCP connections from up to 8 simultaneous clients. When a client sends a Modbus TCP/IP request, the microprocessor translates it into a Modbus RTU query, sends it to the governor via Port 1, receives the response, and returns the data to the Ethernet client in Modbus TCP/IP format. For write operations, the reverse translation occurs: Modbus TCP/IP write → Modbus RTU write → W-Net write command → governor executes. The two isolation transformers provide galvanic isolation (1500 V DC) between all three ports, preventing ground loops and protecting the governor from network transients.
Key Features:
- Triple-protocol support on one module — W-Net, Modbus RTU, Modbus TCP/IP simultaneously
- 8 simultaneous Modbus TCP/IP clients — multiple SCADA stations access the governor without additional hardware
- Dual RS-485 ports with independent configuration — W-Net and Modbus RTU run at different baud rates if required
- Built-in web server — browser-based configuration and real-time data dashboard
- Galvanic isolation (1500 V DC) on all three ports — eliminates ground loops and protects against surges
- ARM Cortex-M4 processor with 256 KB Flash — fast data processing, large buffer for event logging
- Firmware updatable over Ethernet or serial — no physical access required for software upgrades
- 5 LED status indicators — Power, Ethernet Link, W-Net Active, Modbus RTU Active, Fault (visual diagnostics)
Advantages:
- Eliminates need for separate serial-to-Ethernet converters — all three protocols on one compact module
- 8 simultaneous Ethernet clients — supports large SCADA systems with multiple operator stations
- Independent baud rate configuration per serial port — W-Net at 115200 bps and Modbus RTU at 9600 bps simultaneously
- Dual isolation transformers — maximum protection for the governor from both serial and Ethernet side faults
- Web-based configuration — no software installation; configure from any browser on the network
- Large 64 KB RAM buffer — stores up to 10,000 data points for historical trending and event logging
- Firmware-upgradable remotely — reduces service calls; update from anywhere on the network
- Compact DIN rail form factor (35 mm) — fits in standard control panels without additional space
Applicable Industries:
- Power Generation — gas turbine governor remote monitoring, steam turbine control, diesel generator sets, cogeneration plants
- Oil & Gas — remote monitoring of generator drives on offshore platforms, pipeline compressor stations, wellhead power systems
- Mining — remote governor monitoring for mine power generation in inaccessible underground locations
- Marine — shipboard generator control and remote monitoring from bridge or engine room
- Data Centers — UPS and backup generator remote management via Modbus TCP/IP to DCIM
- Commercial Buildings — cogeneration plant integration with building automation via Modbus TCP/IP to BMS
- Industrial Plants — remote monitoring of standby generators in manufacturing facilities, refineries, and chemical plants
- Water / Wastewater — pump station generator remote monitoring via Modbus RTU to SCADA
Model Series:
| Model Number | Protocols Supported | Ethernet Clients | Key Feature |
|---|---|---|---|
| 9907-028 | W-Net + Modbus RTU + Modbus TCP/IP | 8 | Triple protocol, 8 clients, web server |
| 9907-029 | W-Net + Modbus RTU only | N/A | Dual serial, no Ethernet |
| 9907-030 | W-Net + Modbus TCP/IP only | 8 | Serial + Ethernet, no Modbus RTU |
| 9907-031 | Modbus RTU + Modbus TCP/IP only | 8 | Non-Woodward governors, dual protocol |
| 9907-032 | W-Net + BACnet/IP + Modbus TCP/IP | 8 | Triple protocol with BACnet/IP for BMS |
| 9907-033 | W-Net + Profibus DP + Modbus TCP/IP | 8 | Triple protocol with Profibus for Siemens PLCs |
| 9907-034 | W-Net + EtherNet/IP + Modbus TCP/IP | 8 | Triple protocol with EtherNet/IP for Allen-Bradley PLCs |
Compatible Governors:
| Governor Model | Communication Port | Gateway Required |
|---|---|---|
| EasyGen 2500 | RS-485 (W-Net) | 9907-028 |
| EasyGen 3200 | RS-485 (W-Net) | 9907-028 |
| EasyGen 3500 | RS-485 (W-Net) | 9907-028 |
| EasyGen 3800 | RS-485 (W-Net) | 9907-028 |
| EG4-P | RS-485 (W-Net) | 9907-028 |
| EG4-S | RS-485 (W-Net) | 9907-028 |
| EG4-C | RS-485 (W-Net) | 9907-028 |
| EasYgen-3500P | RS-485 (W-Net) | 9907-028 |
| EasYgen-3500P2 | RS-485 (W-Net) | 9907-028 |
Installation Requirements:
- Mount the gateway on a standard 35 mm DIN rail (EN 60715) in the control panel
- Connect the 24 VDC power supply to the 2-pin screw-clamp terminal block on the rear panel (polarity: positive to +, negative to −)
- Connect the Ethernet cable (shielded CAT5e or CAT6) from the gateway RJ-45 port to the plant Ethernet switch
- Connect the W-Net serial cable (RS-485, 4-wire shielded twisted pair) from Port 1 (RJ-45) to the governor’s communication port (J4 or J5) — use blue-sheathed IS cable if routing through hazardous area
- Connect the Modbus RTU serial cable (RS-485, 4-wire shielded twisted pair) from Port 2 (RJ-45) to the SCADA/PLC Modbus RTU port
- Set the gateway IP address via the built-in web server (default: 192.168.1.100) or via governor front panel menu
- Configure the Modbus register mapping in the SCADA/DCS system to match the gateway’s register table (Document 9907-REG-001)
- Ground the gateway chassis to the panel earth bar using the dedicated grounding lug (4 mm² green/yellow wire minimum)
- Verify Power LED is green, Ethernet Link LED is green, and W-Net Active LED is flashing after power-up
Usage Precautions:
- Do not connect the gateway to the Ethernet network before configuring its IP address — IP conflict will cause communication failure with all devices
- Do not exceed 8 simultaneous Modbus TCP/IP connections — additional connections will be rejected
- Do not use unshielded Ethernet cable — EMI from VFDs, motors, and welders will corrupt data in industrial environments
- Do not connect the W-Net serial cable in parallel with other RS-485 devices — W-Net is point-to-point only; daisy-chaining causes communication errors
- Do not connect the Modbus RTU cable in parallel with more than 32 Modbus devices — RS-485 specification limits load to 32 unit loads
- Do not apply voltage exceeding 32 VDC to the power input — this will damage the internal voltage regulator and microprocessor
- Do not expose the gateway to temperatures above +60°C — internal components are rated for a maximum of +60°C
- Do not disable the built-in web server firewall — leaving the web interface unprotected exposes the governor to unauthorized access
- Set a strong password on the web interface — the default password (woodward) must be changed during initial commissioning
- Perform firmware updates only from Woodward-approved sources — unauthorized firmware can brick the module
- Verify register mapping in the SCADA system matches the gateway documentation — mismatched registers cause incorrect data display
- Do not mix W-Net and Modbus RTU cables on the same RS-485 bus — each port is a separate, isolated bus
Certifications:
- CE Marked (EMC Directive 2014/30/EU, Low Voltage Directive 2014/35/EU, Machinery Directive 2006/42/EC)
- UL Listed (File E211762) — for use in North American control panels
- CSA Certified (File LR42403)
- RoHS Compliant (Directive 2011/65/EU)
- REACH Compliant (Regulation EC 1907/2006)
- WEEE Compliant (Directive 2012/19/EU)
- ATEX / IECEx (when used with IS-rated cable in hazardous areas) — Zone 1 / Zone 2 gas, Zone 20 / Zone 21 dust
Documentation Reference:
- Woodward 9907 Series Gateway Module Installation Manual (Document 9907-IM-001)
- Woodward 9907 Series Technical Data Sheet (Document 9907-TDS-001)
- Woodward 9907 Modbus Register Map (Document 9907-REG-001)
- Woodward 9907 Web Configuration Guide (Document 9907-WEB-001)
- Woodward EasyGen Governor Communication Guide (Document EG-COM-001)
- Woodward Gateway Module Selection Guide (Document 9907-SG-001)
Replacement Parts:
| Part Number | Description |
|---|---|
| 9907-PCB-001 | Main circuit board assembly (ARM Cortex-M4) |
| 9907-ETH-001 | RJ-45 Ethernet connector assembly with magnetics |
| 9907-SER-001 | RJ-45 serial connector assembly (Port 1, W-Net) |
| 9907-SER-002 | RJ-45 serial connector assembly (Port 2, Modbus RTU) |
| 9907-LED-001 | LED indicator board assembly (5 LEDs) |
| 9907-TR-001 | Isolation transformer assembly (Port 1) |
| 9907-TR-002 | Isolation transformer assembly (Port 2) |
| 9907-PWR-001 | Voltage regulator assembly (24 VDC input) |
| 9907-TB-001 | Terminal block assembly (2-pin, screw-clamp) |
| 9907-ENC-001 | DIN rail mounting enclosure (ABS) |
| 9907-LAB-001 | Label kit (model, serial, IP, MAC, W-Net address) |
| 9907-FUS-001 | Fuse, 500 mA, fast-acting (internal, user-replaceable) |