Product Short Description
Product Category: Surface-Mounted Pull Station / Manual Fire Alarm Activation Device
Product Overview:
The Honeywell 05704-A-0146 is a surface-mounted manual fire alarm pull station from the Saf-T-Pop product line. It is a UL-listed, manually activated device designed to trigger a fire alarm system when pulled, providing an immediate notification signal to the connected fire alarm control panel.
Description
Function:
Manual activation of fire alarm notification appliances via pulling the handle or operating the lever, sending a supervised signal to the fire alarm control panel (FACP).
Technical Specifications:
| Parameter | Specification |
|---|---|
| Part Number | 05704-A-0146 |
| Manufacturer | Honeywell International Inc. |
| Product Line | Saf-T-Pop |
| Type | Surface-Mounted Pull Station |
| Activation Method | Pull handle / lever |
| Contact Rating | 1A @ 30VDC (N.O. / N.C. contact) |
| Supervision | End-of-line resistor supervised (1kΩ typical) |
| Operating Temperature | -20°C to 60°C (-4°F to 140°F) |
| Storage Temperature | -40°C to 85°C (-40°F to 185°F) |
| Relative Humidity | 0% to 95% non-condensing |
| Listing | UL Listed, ULC Listed, FM Approved |
| Compliance | NFPA 72, CAN/ULC-S524 |
| Color | Red |
| Housing Material | Zinc Die-Cast with Red Powder-Coated Finish |
| Mounting Type | Surface-Mounted |
| Electrical Connection | Screw terminals, 2-wire supervised loop |
| Dimensions (approx.) | 102 mm × 108 mm × 48 mm (4.0 in × 4.3 in × 1.9 in) |
| Weight (approx.) | 0.23 kg (0.5 lb) |
Material Composition:
| Component | Material |
|---|---|
| Housing | Zinc die-cast alloy |
| Finish | Red epoxy powder coat |
| Internal Contact | Silver alloy / gold-plated contacts |
| Handle / Lever | Stainless steel |
| Mounting Plate | Zinc die-cast alloy |
| Gasket | Neoprene rubber (weather seal) |
| Terminal Blocks | Brass / copper alloy |
Structural Features:
- Surface-mounted design with gasketed backplate for weather resistance
- Red lever-style handle for intuitive manual activation
- Tamper-resistant reset mechanism requiring a key or special tool
- Dual N.O./N.C. supervised contact for loop supervision and alarm signaling
- Pre-wired terminal block for simplified field installation
- Flush or surface box compatible — mounts to standard 4-inch square electrical box
- Weatherproof gasket provides IP66 / NEMA 4X rating for outdoor use
Working Principle:
- The pull station is connected to the fire alarm control panel via a 2-wire supervised loop with an end-of-line resistor.
- Under normal conditions, the circuit is supervised; the FACP continuously monitors loop integrity.
- When the red lever is pulled, the internal contacts change state (N.O. closes, N.C. opens), creating an alarm condition.
- The FACP detects the change and initiates alarm notification — audible horns, strobes, voice evacuation, etc.
- The station must be manually reset using a key or authorized tool after activation.
Key Advantages:
- UL Listed / FM Approved — meets the highest fire protection standards
- Surface-mounted with weatherproof gasket — suitable for indoor and outdoor installations
- Tamper-resistant — prevents unauthorized reset or activation
- Supervised loop — detects open, short, or ground fault conditions
- Zinc die-cast housing with powder-coat finish — highly durable, corrosion-resistant
- Simple 2-wire connection — reduces installation time and wiring errors
- Compact form factor — low-profile design blends with modern building aesthetics
Applicable Industries:
| Industry | Application |
|---|---|
| Commercial Buildings | Office towers, shopping malls, retail centers |
| Industrial Facilities | Manufacturing plants, warehouses, refineries |
| Healthcare | Hospitals, clinics, nursing homes |
| Education | Schools, universities, dormitories |
| Hospitality | Hotels, resorts, conference centers |
| Government / Public | Courthouses, airports, transportation hubs |
| Residential (High-Rise) | Apartment complexes, condominiums |
Installation Requirements:
- Mount on a standard 4-inch square electrical box (single-gang or double-gang)
- Use 18 AWG minimum supervised signaling line cable (SLC) — 2 conductors + shield
- Maintain maximum loop length per FACP specifications (typically 3,000 ft / 914 m for Class B)
- Install end-of-line resistor (1kΩ, 1/4W minimum) at the last device on the loop
- Ensure wire connections are tight at screw terminals — no soldering required
- For outdoor mounting, verify gasket is properly seated and box is sealed
- Mounting height: 42 to 48 inches (1067 mm to 1219 mm) from finished floor per NFPA 72 / ADA requirements
- Keep clear of obstructions — minimum 36 inches (914 mm) of clear space in front
Usage Precautions:
- Do not cover or paint the pull station — this violates UL listing and may void warranty
- Do not disconnect the supervised loop without first notifying the fire alarm monitoring company
- Test monthly per NFPA 72 requirements — pull the handle and verify alarm at the control panel
- Reset only with authorized key/tool after each activation or test
- Do not use for non-fire-alarm purposes — false activations are illegal under most fire codes
- Inspect annually for physical damage, corrosion, or gasket degradation
- Replace immediately if housing is cracked, contacts are corroded, or gasket is damaged
- Do not install in areas subject to physical abuse without protective housing or bollards
- Ensure the FACP zone is properly programmed for this device type (pull station, supervised)
Cross-Reference / Compatible Part Numbers:
| Honeywell Part | Description |
|---|---|
| 05704-A-0146 | Saf-T-Pop Surface-Mount Pull Station — Red |
| 05704-A-0141 | Saf-T-Pop Flush-Mount Pull Station — Red |
| 05704-A-0121 | Saf-T-Pop Recessed Pull Station — Red |
| 05704-A-0151 | Saf-T-Pop Surface-Mount Pull Station — White |
Warranty:
Honeywell Saf-T-Pop products carry a limited 5-year warranty from date of manufacture against defects in materials and workmanship under normal use conditions.



-500x500.jpg)

-500x500.jpg)
Reviews
There are no reviews yet.