Product Short Description
Product Introduction
The GE Multilin SR750-P5-G5-S5-HI-A20-R-T is a high‑performance, multi‑processor‑based digital feeder management and protection relay from GE’s Multilin 750/760 series. It is purpose‑engineered for comprehensive protection, monitoring, control, and automation of medium‑voltage distribution feeders, substation feeders, and industrial power feeders across utility and industrial power systems. This model features 5A phase current inputs (P5), 5A ground current inputs (G5), 5A sensitive ground current inputs (S5), a universal high‑voltage control power supply (HI), enhanced analog output configuration (A20), a draw‑out chassis (R), and an enhanced display with integrated Ethernet (T). It integrates advanced feeder protection algorithms, precise metering, flexible I/O, and robust communication capabilities, delivering ultra‑fast fault clearance and comprehensive feeder health monitoring for critical power distribution assets.
Description
Technical Specifications
Electrical Specifications
- Phase Current Input: P5 = 5 A (5A nominal phase CT secondary current)
- Ground Current Input: G5 = 5 A (5A nominal zero‑sequence ground fault current input)
- Sensitive Ground Current Input: S5 = 5 A (5A nominal sensitive ground fault current input)
- Control Power Supply: HI = 88–300 VDC / 70–265 VAC @ 48–62 Hz (universal wide‑range high‑voltage power)
- Voltage Inputs: 3‑phase voltage inputs (30–300 V nominal) for bus/line voltage monitoring
- Digital Inputs: 8 opto‑isolated, programmable digital inputs for breaker status, remote control, and status signaling
- Relay Outputs: 8 configurable Form A/C relay outputs for tripping, alarming, control, and signaling functions
- Analog Outputs: A20 = 8 programmable 4–20 mA / 0–20 mA analog channels for metering and process signaling
- Communication Ports: RS‑232 (front), RS‑485/RS‑422 (rear); integrated 10 Mbps Ethernet port (T) supporting Modbus TCP/IP, DNP3, and IEC 61850
- Measurement Accuracy: Current ±1% FS; voltage ±0.5% FS; power ±0.5% FS; frequency ±0.1% FS
- Relay Operating Time: ≤ 1 cycle (≤ 16.6 ms @ 60 Hz) for main protection elements
- Overload Withstand: 1 second at 40 × rated current; continuous operation at 2 × rated current
- Frequency Range: 45–65 Hz (auto‑sensing)
- Burden: < 0.025 VA at 120 V for voltage inputs
- Analog Input Impedance: 375 Ω ± 10%
- Communications Baud Rate: 300 to 19200 baud
Environmental & Physical Specifications
- Operating Temperature: -25°C to +70°C (-13°F to +158°F)
- Storage Temperature: -40°C to +85°C (-40°F to +185°F)
- Relative Humidity: Up to 90% (non‑condensing)
- Pollution Degree: 2
- Ingress Protection: IP40 (front panel)
- Dimensions: 7” W × 6.5” D × 8.5” H (177.8 mm × 165.1 mm × 215.9 mm)
- Weight: Approximately 7.6 kg (16.8 lbs)
- Mounting: Panel‑mount with draw‑out chassis design (R)
- Display: Enhanced backlit LCD display (T) with keypad and status LEDs
- Certifications: Compliant with IEEE, ANSI, NEMA, IEC 61010‑1, UL, cUL, and CE standards
Key Features
- Comprehensive Feeder Protection: Delivers complete protection including overcurrent, ground fault, sensitive ground fault, directional overcurrent, under/overvoltage, under/overfrequency, phase imbalance, negative sequence, breaker failure, and feeder automation functions.
- Ultra‑Fast Fault Clearing: Multi‑processor architecture provides sub‑cycle operating times for critical protection elements, minimizing feeder downtime and equipment damage during faults.
- Advanced Metering & Monitoring: Provides precise measurement of voltage, current, power, energy, demand, load‑to‑trip percentage, and harmonic analysis (THD) for comprehensive feeder performance monitoring.
- Flexible I/O & Configuration: 8 digital inputs, 8 relay outputs, and 8 analog outputs support custom protection schemes and integration with legacy and modern control systems.
- Enhanced User Interface (T): Features an enhanced backlit LCD display with intuitive keypad for local configuration, parameter viewing, and fault diagnostics.
- Event & Fault Recording: Logs 512 time‑stamped events, detailed fault data, and oscillographic waveform captures for rapid troubleshooting and post‑fault analysis.
- Draw‑Out & Hot‑Swappable Design (R): Allows module replacement without system shutdown, minimizing downtime during maintenance.
- Robust Integrated Communication (T): Built‑in Ethernet port supports multiple industrial protocols for seamless integration with PLCs, DCS, SCADA, and power management systems.
- Harsh Environment Resilience: Operates reliably in extreme temperatures and industrial environments with high humidity and vibration.
- Self‑Diagnostics: Built‑in self‑monitoring and fault detection ensures continuous operational integrity.
- EnerVista Software Compatibility: Configurable and monitored via GE’s EnerVista 750 Setup Software for easy setup, remote management, and firmware updates.
- Breaker Status Indication: Integrated red LED for direct breaker closed status visibility.
- Security Features: Hardware and passcode security to lock out unauthorized configuration changes.
Application Scenarios
- Power Distribution: Primary protection for medium‑voltage distribution feeders, substation feeders, and radial feeders in utility grids.
- Industrial Facilities: Feeder protection for factories, refineries, chemical plants, and heavy industrial sites with critical power distribution needs.
- Mining & Minerals: Protection of power feeders in mining operations, ore processing, and material handling facilities.
- Oil & Gas Industry: Feeder management for onshore/offshore drilling rigs, production platforms, and pipeline pumping stations.
- Water & Wastewater: Protection for feeders in water treatment plants, pump stations, and desalination facilities.
- Data Centers: Critical feeder protection for mission‑critical data center power distribution systems.
- Commercial Buildings: Feeder management in large commercial complexes, hospitals, and high‑rise buildings.
- Renewable Energy: Integration with wind and solar farms for feeder protection in renewable energy installations.
- Marine & Offshore: Feeder protection for marine vessels, offshore support platforms, and floating production systems.
- Chemical & Petrochemical: Designed for harsh chemical environments with conformal coating options.





Reviews
There are no reviews yet.