The NBRA-659C is an external braking chopper module from ABB for use with any 400 V or 500 V three-phase inverter that provides access to the DC+ and DC- terminals. It dissipates regenerative braking energy in an external resistor, preventing over-voltage trips on ABB ACS800, ACS850 and ACS550 drives as well as any other make of drive suffering from extended stop ramps.
Description
Technical Specifications
Rating with 400 V inverter: 352.8 kW part-time (60 seconds every 10 minutes), 30 kW continuous
Rating with 500 V inverter: 268.1 kW part-time (60 seconds every 10 minutes), 18 kW continuous
Minimum external resistor: 1.2 Ω (400 V operation), 2 Ω (500 V operation)
Supply voltage setting: adjustable for 230 V, 400 V and 500 V drives
Parallel connection: supported for higher braking powers
Dimensions: 334 mm wide × 240 mm deep × 583.5 mm high
Mounting: 4 × 7 mm holes at 200 × 562 mm for rear mounting
Enclosure rating: IP00
Weight: 26 kg
Heat loss: approximately 1 % of the braking power
Cooling fan kits: 230 V (64114158) or 115 V (64114191)
EAN: 6438177017059; replaced product ID: 58930822; origin Finland/Estonia
Functional Features
Simple setup, universal compatibility with third-party drives via DC link terminals, adjustable voltage threshold, scalable through parallel connection, and standardized ABB resistor compatibility (SAFUR series).
Application Scenarios
Cranes and hoists, decanter centrifuges, downhill conveyors, test benches, saw lines, and any application with high inertia or frequent braking where drive over-voltage faults occur.
Structural Features
The module contains the chopper power stage with semiconductor switches, DC link connection terminals (UDC+, UDC-), resistor terminals (R+, R-), grounding clamps and a control board connection for the drive; it is an open-frame IP00 module designed for installation inside a cabinet with 150 mm free space above and below.
Working Principle
When the DC link voltage of the drive rises above the adjustable threshold during braking, the chopper switches on and connects the external braking resistor across the DC link, converting the regenerated energy into heat; when the voltage falls below the threshold the resistor is disconnected.
Installation Requirements
Rear-mount the module with four M7 screws on the 200 × 562 mm hole pattern, connect UDC+/UDC- to the drive DC link and R+/R- to the external resistor using M10 terminals (tightening torque 26 N·m / 35 lbf·ft maximum), set the supply voltage adjustment for 230/400/500 V, and install the cooling fan kit.
Precautions
Respect the minimum resistor values of 1.2 Ω (400 V) and 2 Ω (500 V) to avoid chopper overcurrent, keep 150 mm free space above and below the module for cooling, observe that the module is IP00 and must be installed in an enclosure, and derate output power above 1000 m altitude.