Product Short Description
Product Introduction
The ABB SPAJ140 C is a microprocessor-based, combined overcurrent and earth-fault protection relay, belonging to the SPACOM product family. It is designed for selective short-circuit and earth-fault protection of radial feeders in solidly-earthed, resistance-earthed, or impedance-earthed power systemsABB. This integrated unit combines phase overcurrent protection, non-directional earth-fault protection, and built-in circuit-breaker failure protection, offering flexible tripping and signaling capabilities. It features comprehensive self-supervision, local/remote parameterization, and data communication, making it a robust solution for medium-voltage distribution network protection.
Description
Technical Specifications
- Product Type: Microprocessor-based combined overcurrent and earth-fault relay
- Protection Functions:
- Three-phase low-set phase overcurrent (definite time or IDMT characteristic)
- Three-phase high-set phase overcurrent (instantaneous or definite time)
- Low-set non-directional earth-fault (definite time or IDMT characteristic)
- High-set non-directional earth-fault (instantaneous or definite time)
- Built-in circuit-breaker failure protection
- Time-Current Curves: Four standard IDMT curves (IEC/BS), plus RI and RXIDG specific inverse-time characteristics
- Input Current Ratings: 1 A or 5 A (CT secondary)
- Auxiliary Power Supply: Wide-range DC (24–250 V DC) or AC (100–240 V AC, 50/60 Hz)
- Output Relays: 2 heavy-duty tripping relays + 4 light-duty signaling relays (configurable matrix)
- Communication Interface: Serial port for local/remote access to parameters, fault logs, and diagnostics
- Display: Numerical readout for measured values, settings, fault records, and status codes
- Self-Supervision: Continuous hardware/software monitoring with auto-diagnosisABB
- Operating Temperature: -10°C to +55°C
- Humidity: 5%–95% RH (non-condensing)
- Protection Degree: IP54 (aluminum case for harsh/offshore environments)
- Certifications: IEC 60255, CE, UL, and marine/offshore compliance
- Mounting: Panel-mounted or rack-mounted
- Dimensions: Standard industrial form factor (approx. 144 mm × 144 mm × 220 mm)
- Weight: Approx. 3.5 kg
Key Features
Integrated Multi-Protection Design
- Combined Functionality: Integrates phase overcurrent, earth-fault, and breaker failure protection in one unit, reducing panel space and wiring complexityABB.
- Dual Protection Stages: Each protection function includes low-set (back-up) and high-set (instantaneous) stages for selective coordination.
- Flexible Time Characteristics: Supports both definite time and multiple IDMT curves for precise protection coordination in complex networks.
Advanced Communication & Configuration
- Serial Connectivity: Built-in serial port enables remote parameter setting, fault data retrieval, and integration with SCADA/automation systems.
- Local/Remote Operation: Full control via front-panel keypad/display or portable PC software.
- Fault Memory: Records fault parameters, current values, and event logs for post-fault analysis.
Robust Reliability & Diagnostics
- Continuous Self-Supervision: Monitors microprocessor, power supply, and I/O circuits; alerts on internal faultsABB.
- High Electromagnetic Immunity: Designed to withstand industrial EMI, ensuring stable operation in substations.
- IP54 Enclosure: Dust and water-resistant aluminum housing for offshore and harsh industrial sites.
Flexible Output & Control
- Configurable Relay Matrix: Outputs can be freely assigned to trip, alarm, or status signals.
- External Control Input: Accepts blocking signals, remote reset, or setting selection via terminal 10–11.
- Visual Indicators: LED and numerical display for real-time status, fault codes, and measured values.
Application Scenarios
Medium-Voltage Distribution Networks
- Radial Feeders: Primary protection for overhead lines and cables in urban/rural distribution gridsABB.
- Substation Feeders: Selective protection in distribution substations with solid/resistance/impedance groundingABB.
- Distribution Transformers: Backup overcurrent and earth-fault protection for distribution transformers.
Industrial Power Systems
- Oil & Gas Facilities: Protection for pumps, compressors, and process loads in refineries and offshore platforms.
- Mining Operations: Reliable protection for heavy machinery and conveyor systems in underground mines.
- Manufacturing Plants: Overcurrent/earth-fault protection for motor control centers and industrial distribution boards.
- Marine & Offshore: IP54-rated units for shipboard power distribution and offshore platform protection.
Infrastructure & Utilities
- Water & Wastewater: Protection for pump stations and treatment plant electrical systems.
- Renewable Energy: Grid interconnection protection for wind farms and solar power plants.
- Railway Electrification: Feeder protection for DC/AC traction power supply systems.
Legacy System Retrofits
- Substation Modernization: Upgrading electromechanical relays with microprocessor-based SPAJ140 C for improved selectivity and diagnostics.
- System Expansion: Adding protection to existing distribution networks without major rewiring.






Reviews