Product Short Description
Product Introduction
The ABB 1SAM340000R1011, designated as MS132‑16T, is a compact, high‑performance electromechanical circuit breaker purpose‑built for primary‑side protection of control transformers. It delivers fuse‑less protection against overloads and short‑circuits, with a fixed short‑circuit trip setting of 20 times the rated operational current to reliably handle the high inrush currents inherent to transformers. This device integrates manual disconnect functionality, enabling safe on‑site connection and isolation of transformers from the power supply. Designed for industrial and utility environments, it combines robust performance, high breaking capacity, and user‑friendly operation to ensure reliable transformer and system protection.
Description
Technical Specifications
Electrical Parameters
- Rated Operational Current (Ie): 16 A
- Rated Voltage: Up to 690 V AC / 250 V DC
- Frequency: 50/60 Hz
- Short‑Circuit Trip Setting: Fixed at 20 × Ie (320 A)
- Rated Service Short‑Circuit Breaking Capacity (Ics): 100 kA at 400 V AC
- Trip Class: Class 10 (fast‑acting overload protection)
- Overload Protection: Thermal‑magnetic trip mechanism with temperature compensation
- Short‑Circuit Protection: Magnetic instantaneous trip
- Disconnect Function: Integrated manual ON/OFF switching
- Terminals: Screw terminals (compatible with flexible 0.75–2.5 mm², rigid 1–4 mm² wires)
Mechanical & Environmental
- Dimensions: 45 mm (W) × 97.8 mm (H) × 86.05 mm (D)
- Weight: 0.31 kg
- Mounting: DIN‑rail mount (TH35‑15 / TH35‑7.5 per IEC 60715)
- Operating Temperature: -25 °C to +70 °C
- Storage Temperature: -40 °C to +85 °C
- Humidity: 5–95% RH (non‑condensing)
- Ingress Protection: IP20 (front face)
- Mechanical Life: ≥ 10,000 operating cycles
- Standards Compliance: IEC 60947‑2, IEC 60947‑4‑1, CE marked
Key Features
- Fuse‑Less Dual Protection: Provides comprehensive protection against both overloads and short‑circuits without requiring fuses, reducing maintenance and replacement costs.
- Transformer‑Optimized Trip Curve: Fixed 20×Ie short‑circuit setting is engineered to withstand transformer inrush currents while ensuring rapid fault clearing.
- High Breaking Capacity: 100 kA breaking capacity at 400 V AC delivers reliable interruption of severe short‑circuit faults in industrial power systems.
- Temperature‑Compensated Tripping: Maintains consistent protection performance across the full operating temperature range, eliminating drift due to environmental changes.
- Trip‑Free Mechanism: Ensures the breaker trips even if the handle is held in the ON position, guaranteeing fault isolation.
- User‑Friendly Rotary Handle: Features clear ON/OFF/TRIP position indication and is lockable to prevent unauthorized operation or adjustments.
- Short‑Circuit Trip Indicator: Provides visual confirmation of a magnetic short‑circuit trip event.
- Compact Design: 45 mm width saves valuable panel space, ideal for dense control cabinet installations.
- Flexible Accessories: Supports auxiliary contacts, signaling contacts, undervoltage releases, shunt trips, and power in‑feed blocks for expanded functionality.
Application Scenarios
- Control Transformer Primary Protection: Primary protection device for low‑voltage control transformers in industrial control panels, motor control centers (MCCs), and automation systems.
- Industrial Automation Panels: Protects transformers powering PLCs, HMI systems, relays, and other control components in manufacturing and process automation setups.
- Power Distribution Systems: Used in distribution boards and switchgear to safeguard transformers feeding auxiliary circuits in utility and industrial power networks.
- Motor Control Centers (MCCs): Integrated into MCCs to protect control transformers that supply power to motor starters, contactors, and instrumentation.
- Building Automation: Protects transformers in HVAC control systems, lighting control panels, and building management systems (BMS).
- OEM Equipment: Standard protection component for original equipment manufacturers (OEMs) integrating control transformers into machinery and production lines.
- Renewable Energy Systems: Safeguards control transformers in solar inverter stations, wind turbine control cabinets, and energy storage systems.





Reviews
There are no reviews yet.