Product Short Description

Product Introduction:

The IC670CHS002 is a 2‑slot box‑style I/O terminal block for GE Fanuc Field Control systems, serving as a wiring base for I/O modules (digital/analog input/output, specialty modules) with catalog number suffix J or above. It provides backplane communication, secure module mounting, and field wiring terminals, supporting up to 2 modules that screw onto the base for vibration resistance while allowing hot‑swap without disturbing field wiring. The block features 37 terminals organized into 3 isolated common groups (A, B, E) plus 16 I/O point terminals, with 1500VAC isolation between groups and the backplane for noise immunity. It accommodates one AWG #14 or two AWG #18–22 wires per terminal, with 4.5in‑lb torque and 10A per‑terminal current capacity. The terminal block mounts on standard DIN rails, weighs 0.03kg (0.06 lbs), and integrates seamlessly with Field Control BIUs and host PLCs for reliable I/O connectivity in industrial automation.

Description

  • Technical Specifications:
    • Physical Configuration: 2‑slot terminal block; 37 total terminals (16 I/O point terminals + 3 common terminal groups)
    • Terminal Capacity: One AWG #14 (2.1 mm²) or two AWG #18–22 (0.35–0.86 mm²) copper wires; 194°F (90°C) wire rating
    • Terminal Ratings: 4.5in‑lb recommended torque; 10A maximum current per terminal; 600VAC/VDC voltage rating
    • Isolation: 1500VAC between common groups (A, B, E) and backplane (1 minute); 250VAC continuous isolation to case
    • Common Terminal Groups: Group A (internally connected, power); Group B (internally connected, power); Group E (5 terminals, internally tied, isolated from power/point terminals)
    • Module Compatibility: I/O modules with catalog number suffix J or above; supports digital, analog, and specialty I/O modules
    • Mounting: Standard DIN rail mount (35mm); panel mount optional
    • Physical Dimensions: 105mm x 45mm x 25mm (4.13″ x 1.77″ x 0.98″); weight 0.03kg (0.06 lbs)
    • Environmental: 0°C to 55°C operating temperature; -40°C to 85°C storage temperature; 5%–95% RH (non‑condensing)
    • Hot‑Swap: Supported; modules can be removed/installed without powering down the system
  • Function Features:
    • 2‑Slot Modular Design: Accommodates up to 2 I/O modules, enabling flexible I/O expansion for small to medium‑scale control systems.
    • Secure Mounting: Modules screw onto the terminal block to resist vibration, ensuring stable operation in industrial environments.
    • Hot‑Swap Capability: Allows module replacement without disturbing field wiring or powering down the system, minimizing downtime.
    • Isolated Common Groups: 3 isolated common terminal groups prevent ground loops and noise interference, ensuring signal integrity.
    • High Terminal Capacity: Supports multiple wire gauges and high current (10A) for diverse field device connections.
    • Easy Integration: Works with all Field Control BIUs and host PLCs; mounts on standard DIN rails for quick installation.
    • Backplane Communication: Provides reliable data transfer between I/O modules and the host PLC via the backplane bus.
  • Application Scenarios:
    • Process Control: Serves as a wiring base for I/O modules monitoring temperature, pressure, flow, and level in chemical, water/wastewater, and food/beverage plants.
    • Manufacturing Automation: Connects digital I/O modules to sensors/actuators and analog modules to variable speed drives in automotive, electronics, and packaging lines.
    • OEM Machinery: Integrates with custom equipment requiring modular I/O expansion for closed‑loop control and predictive maintenance.
    • Building Automation: Supports HVAC, lighting, and energy management systems with reliable I/O connectivity for environmental control.
    • Distributed I/O Systems: Extends I/O capabilities to remote plant floor areas when paired with Field Control BIUs for centralized monitoring/control.
  • Installation & Maintenance:
    • Mounting: Snap onto standard 35mm DIN rail; ensure proper grounding for noise immunity and signal stability.
    • Module Installation: Align modules with the terminal block’s alignment slots; secure with screws to prevent vibration‑induced disconnection.
    • Wiring: Connect field devices to I/O point terminals (1–16) and power to common groups (A, B); use shielded cables for analog signals to minimize interference.
    • Torque Application: Tighten terminal screws to 4.5in‑lb for secure connections and optimal electrical performance.
    • Hot‑Swap Procedure: Power down the module (if required); remove screws, lift the module, and replace without disconnecting field wires; re‑secure and power up.
    • Troubleshooting: Check terminal connections for tightness; verify wire gauge compatibility; use a multimeter to confirm signal integrity and isolation between groups.
  • Certifications: UL Listed, CE marked; compliant with IEC 61010‑1 safety standards and IEC 61326‑1 EMC standards for reliable operation in harsh industrial environments.