Product Short Description

Product Introduction

As a key model in the GE Multilin 489 series, this relay is tailored to protect and manage generators in low-voltage industrial power systems, integrating precise fault detection, performance monitoring, and data logging capabilities. It uses 5A phase CT secondary inputs for accurate current measurement, a low-voltage control power supply (20-48 VAC/24-60 VDC) to match low-voltage power systems, and 4 configurable 4-20 mA analog outputs for seamless integration with SCADA/DCS systems. The relay leverages a dual-processor architecture to detect electrical and thermal faults instantly, continuously track generator performance metrics, and log detailed event data for maintenance optimization. It integrates smoothly with generator control panels and supervisory systems via standard communication ports, maximizing uptime, reducing operational costs, and ensuring safe, efficient generator operation in low-voltage industrial environments. It combines comprehensive protection, real-time monitoring, and actionable diagnostics to extend generator service life and enhance power generation efficiency.

Description

Technical Specifications

Specification Details
Series GE Multilin 489 Generator Management Relay
Product Type 5A Phase CT Low-Voltage Generator Management Relay with 4 Analog Outputs
Control Power Supply LO: 24-60 VDC / 20-48 VAC (48-62 Hz), 25 VA typical power, 45 VA maximum power
Phase Current Inputs P5: 5 A nominal (CT-connected); frequency range 20-100 Hz; True RMS conversion, accuracy ±0.5% at <2x CT, ±1% at >2x CT; CT withstand: 80x rated current (1s), 40x (2s), 3x (continuous)
Ground Current Input 5 A nominal (dedicated ground CT input); frequency range 20-100 Hz
Voltage Input Phase VT secondary 200 V AC (full-scale), neutral VT 100 V AC; VT ratio 1.00-240.00:1; accuracy ±0.5% of full scale; max continuous 280 V AC
Analog Outputs A20: 4 analog outputs (4-20 mA), configurable for current, voltage, power, frequency, or temperature signals; accuracy ±1% of full scale
RTD Inputs Supports RTD types: 100Ω platinum, 100Ω nickel, 120Ω nickel, 10Ω copper for stator winding/bearing temperature monitoring; up to 12 RTD inputs with voting feature for redundancy
Digital Inputs 8 opto-isolated digital inputs for external control/interlock signals (24 V DC, 6 mA sinking current)
Output Relays 8 Form-C contacts, rated 5 A at 250 V AC and 0.5 A at 30 V DC
Communication Interfaces Isolated RS-485 (Modbus RTU, DNP 3.0), non-isolated RS-232 port for local configuration and EnerVista software connection
Operating Temperature -40°C to +70°C
Storage Temperature -40°C to +85°C
Enclosure Protection Front panel IP40; NEMA 1/IP10 when mounted in control cabinet
Dimensions (H x W x D) 296 mm x 107 mm x 205 mm
Weight 7.7 kg (approximate)
Event Recorder Stores up to 200 fault events with time stamps; security audit trail for operational accountability
Waveform Capture Oscillography with 128 samples per cycle for voltage/current post-fault analysis
Power Consumption 25 VA typical, 45 VA maximum
Trip Holdup Time 200 ms non-failsafe; 100 ms failsafe
Certifications UL, CSA, CE compliant; meets IEC 61850, IEEE/ANSI C37.90.1 standards
Maximum Altitude 2000 m
Overvoltage Category II
Impulse Voltage Withstand 5 kV
Fuse Model 5×20 mm HRC SLO-BLO, Littelfuse 215-02.5
RTD Input Isolation 36 Vpk
Vibration Resistance Class 1 Sinusoidal

Function Characteristics

  • 5A Phase CT Compatibility: P5 5A phase CT secondary inputs ensure accurate current measurement and protection for generators with 5A CT installations, eliminating the need for CT ratio adapters.
  • Low-Voltage Power Supply: 24-60 VDC / 20-48 VAC input matches low-voltage industrial power systems, ensuring stable operation in low-voltage generator setups.
  • 4 Configurable Analog Outputs: A20 4-20 mA outputs transmit real-time generator parameters (current, voltage, power, frequency, temperature) to SCADA/DCS for centralized monitoring and control.
  • Comprehensive Generator Protection Suite: Delivers stator differential (dual-slope CT saturation immune), 100% stator ground fault (third harmonic adaptive), loss of excitation (negative mho), reverse power (anti-motoring), overexcitation, overcurrent, undervoltage, overvoltage, underfrequency, and breaker failure protection to cover all critical generator fault scenarios.
  • Advanced Diagnostics: Enhanced generator diagnostics, extended event logging, security audit trail, and oscillography enable root-cause analysis, minimizing downtime and optimizing maintenance schedules.
  • Flexible I/O Configuration: 8 digital inputs and 8 Form-C outputs are customizable for control, alarm, and interlock functions, supporting integration with external safety systems.
  • Waveform Capture: 128-samples-per-cycle oscillography captures voltage/current waveforms for detailed post-fault analysis and system optimization.
  • Seamless System Integration: Isolated RS-485 (Modbus RTU, DNP 3.0) and RS-232 ports support connection to SCADA, DCS, and other industrial control systems for centralized monitoring and remote management.
  • RTD Temperature Monitoring: Supports up to 12 RTDs of multiple types for direct temperature measurement of generator windings and bearings, with voting feature for redundancy to enable early detection of thermal issues.
  • Synchrocheck Function: Integrated synchrocheck with slip frequency measurement ensures safe generator paralleling operations.

Application Scenarios

  • Small Industrial Power Plants: Protects and manages auxiliary generators in thermal, hydro, and cogeneration plants, with low-voltage power supply matching small-scale power systems and 5A CT compatibility for standard generator installations.
  • Renewable Energy Installations: Safeguards small wind turbine generators, solar inverter-connected generators, and energy storage system generators, with 5A CT compatibility and 4 analog outputs for remote monitoring and grid integration.
  • Oil and Gas Industry: Manages small generators in remote well sites, pipeline pump stations, and refinery auxiliary systems, adapting to low-voltage power setups and remote operating environments, with 4 analog outputs for SCADA integration.
  • Data Centers & Critical Facilities: Protects low-voltage backup generators, with low-voltage power supply matching facility power systems and enhanced diagnostics ensuring reliable operation in mission-critical environments.
  • Commercial Buildings & Infrastructure: Manages standby generators in shopping malls, hospitals, and office complexes, with low-voltage power supply and 4 analog outputs for integration with building management systems.
  • Marine Power Systems: Controls small shipboard generators in auxiliary power systems, with low-voltage power supply and generator-specific protection functions ensuring safe operation in marine environments.
  • Distributed Generation Systems: Safeguards small distributed generators in microgrids and industrial cogeneration systems, with seamless integration into low-voltage grid control systems via standard communication protocols and 4 analog outputs for power quality monitoring.

Additional Information

  • Configuration Software: Compatible with GE Multilin EnerVista 489 software for remote configuration, real-time monitoring, and data logging, including analog output parameter setup.
  • User Manual: Official user manual (GEK-106613C) provides detailed installation, configuration, and troubleshooting guidelines, including 5A CT integration steps and low-voltage power supply setup procedures.
  • Warranty: 12-month standard warranty, with extended warranty options available for critical applications in harsh environments.
  • Replacement Compatibility: Directly replaces older 489 series relays, with backward-compatible wiring and programming for seamless upgrades in low-voltage generator systems.
  • Maintenance Requirements: Minimal maintenance; annual calibration of current inputs and software updates recommended; analog output calibration every 2 years for accuracy; periodic inspection of low-voltage power supply connections to ensure stable operation.
  • Environmental Compliance: Meets pollution degree II, overvoltage category II requirements for safe operation in industrial settings.

Reviews

There are no reviews yet.

Be the first to review “GE 489-P5-LO-A20”

Your email address will not be published. Required fields are marked *

View Related Products