Product Short Description
Technical Specifications
- Input Channels: 1
- Input Types: Switch, proximity switch (NAMUR/BS EN 60947-5-6:2001), 2/3-wire voltage/pulse transmitters
- Output Types:
- Pulse output (safe zone): Frequency range 0-50kHz (pulse mode), 0-10kHz (analog mode)
- Analog output: Configurable via software
- Alarm output: Relay contact (0.5A @ 35V DC max)
- Isolation Voltage: High-voltage isolation between input, output, and power circuits (up to 1500V DC/AC)
- Power Supply: 20-35V DC (65mA @ 24V DC, 70mA @ 20V DC, 55mA @ 35V DC)
- Response Time: Typically ≤10μs
- Mounting: DIN rail
- Operating Temperature: -20°C to +60°C
Description
- Hazardous Area Approvals:
- Switch/proximity switch input: Zone 0, IIC, T6 (Group A)
- Transmitter input: Zone 0, IIC, T4-T6 (Group A, with proper certification)
- LED Indicators:
- Green: Power on
- Yellow: Output circuit active
- Red: Line fault or error detected
Functional Features
- Pulse Isolation: Isolates high-frequency pulse signals from hazardous areas to safe zones.
- Signal Conversion: Converts pulse signals into analog signals and configurable alarm point signals.
- Software Configuration: Pulse conversion parameters (e.g., switching points, hysteresis) can be set via computer software.
- Line Fault Detection (LFD): Detects open or short circuits in field wiring and triggers alarm outputs.
- NAMUR Compliance: Supports NAMUR-compliant sensors with adjustable switching points (3V, 6V, or 12V).
- High Isolation Voltage: Ensures electrical isolation between hazardous and safe areas, preventing interference.
- DIN Rail Mounting: Compact design for easy installation in control panels.
- LED Diagnostics: Visual indicators for power status, output activity, and fault conditions.
Application Scenarios
- Oil and Gas Industry: Monitors valve positions, pressure switches, or limit switches in explosive atmospheres.
- Chemical Processing: Safely isolates signals from sensors in corrosive or hazardous production areas.
- Power Generation: Isolates signals from high-voltage equipment to low-voltage control systems in power plants.
- Water and Wastewater Treatment: Controls pump and valve actuators while maintaining electrical isolation in wet environments.
- Pharmaceutical Manufacturing: Ensures electrical safety in clean rooms by isolating signals from fermentation tanks and temperature controllers.
- Mining Industry: Provides reliable signal transmission in underground mines for ventilation and gas monitoring systems.
- Factory Automation: Integrates with DCS (Distributed Control Systems) and PLC (Programmable Logic Controllers) for seamless automation control.
- Other Hazardous Areas: Suitable for any application requiring safe signal isolation in environments where explosive gases, vapors, or dust may be present.
Advantages
- Enhanced Safety: Intrinsic safety design prevents electrical sparks, making it suitable for Zone 0 hazardous areas.
- High Performance: Supports high-frequency pulse isolation and analog signal conversion for precise control.
- Flexible Configuration: Software-configurable parameters allow customization for different applications.
- Reliable Fault Detection: Line fault detection ensures system integrity by identifying wiring issues.
- Compact Design: DIN rail mounting saves space in control panels.
- Global Certifications: Meets international safety standards for global applications.





Reviews