Product Short Description
- Technical Specifications
- Electrical Parameters: The operating voltage is 24V AC with a working frequency of 60Hz. The maximum valve load it can bear is 1A for the pilot valve and 1A for the main valve. It relies on a single igniter-sensor rod for ignition and flame detection, and is typically compatible with gas controls such as VR8204 and VR8304, as well as ignition hardware like Q345 and Q3451.
- Timing Parameters: It has no pre-purge phase before ignition, and the ignition trial duration is 90 seconds. It adopts a continuous retry mode for ignition trials without lockout timing. After a failed ignition attempt, there is a 5-minute delay before the next ignition trial. The maximum response time for flame failure is 2 seconds, enabling rapid reaction to abnormal flame conditions.
- Physical Parameters: The product has a width of 5.44 inches which is 138mm, a height of 3.94 inches which is 100mm, and a depth of 2.63 inches which is 67mm. It features a compact structure that facilitates installation in the limited space inside heating equipment control compartments.
- Environmental Parameters: The ambient operating temperature ranges from -40°F to 175°F, which converts to -40°C to 79°C. This wide temperature range allows the module to operate stably in both extremely cold outdoor equipment rooms and high-temperature internal environments of heating appliances.
Description
- Functional Features
- Continuous Retry for Ignition: It adopts a continuous retry ignition sequence instead of locking out after ignition failure. After a failed 90-second ignition trial, it initiates another ignition attempt after a 5-minute delay. This design greatly improves the success rate of ignition, especially in scenarios where temporary gas supply instability may cause ignition failures.
- Rapid Flame Failure Response: It can detect flame abnormalities within a maximum of 2 seconds. Once flame failure is identified, the module immediately triggers the safety shutoff procedure to cut off the gas supply of the pilot valve and main valve, preventing gas leakage and eliminating potential fire or explosion hazards.
- Broad Fuel and Equipment Compatibility: It is designed to work with two common fuels, natural gas and liquefied petroleum gas, adapting to different fuel supply conditions in residential and commercial settings. It is also compatible with specific gas controls and ignition hardware, enabling seamless integration with a wide range of intermittent pilot central furnaces and heating appliances.
- CSA-Certified Reliability: The product has obtained CSA design certification, which indicates it meets strict industry safety and performance standards. Its structural and electrical designs comply with relevant industrial regulations, ensuring safe and stable operation during long-term use without malfunctions due to harsh working conditions.
- Application Scenarios
- Residential Central Furnaces: It is widely installed in residential central heating furnaces. It controls the ignition and flame monitoring of the furnace, ensuring the furnace can ignite reliably when the room temperature drops below the set value and shut down safely when the temperature reaches the standard, providing a stable and safe heating environment for families.
- Light Commercial Heating Appliances: In small commercial spaces such as convenience stores, small office buildings and community clinics, it is used to match small-scale heating equipment. It maintains the normal operation of these heating appliances, ensuring a comfortable temperature for customers and employees while meeting the safety requirements of commercial places for heating equipment.
- Residential Boilers: It is applied to residential gas boilers that supply hot water and heating. It precisely controls the ignition process of the boiler and monitors the combustion flame in real time. It prevents gas leakage caused by flame failure and ensures the continuous and safe supply of hot water and heating for residents.
- Small-Scale Industrial Auxiliary Heating Equipment: In some light industrial workshops that require constant temperature environments for production, such as small electronic component processing workshops and precision instrument maintenance workshops, it is used in auxiliary heating systems. It ensures the stable operation of heating equipment, providing a suitable temperature environment for production and maintenance work.