Product Short Description

Product Overview
The 3BHB017693R0001 is a safety monitoring relay, type BD 5935.48/61 with 24 VDC coil, supplied by ABB as an original spare for the ACS 6000 medium-voltage drive. Procurement records from mine hoist and steel-plant maintenance programs identify it as the “safety relay” component of the ACS6000 converter, and the current successor is order number 68711894 (BD5935.48/61-DC24).

Description

Technical Specifications
Device type: safety relay BD 5935.48/61. Coil voltage 24 VDC. Function: monitoring of safety circuits in the drive system, with positively guided (force-guided) output contacts for integration into the emergency-stop and safety-interlock chain. Mounting on the ACS6000 control panel as a plug-in or base-mounted relay per the cabinet wiring design. Replacement type: BD5935.48/61-DC24 under ABB order number 68711894.
Functional Features
Force-guided contact set guaranteeing that normally open and normally closed contacts never close simultaneously, which permits the contact state to be monitored by external safety circuits. 24 VDC control voltage matching the drive’s internal control supply. High mechanical and electrical endurance for continuous duty in the safety chain of a running converter.
Applications
Safety-chain monitoring in ABB ACS 6000 medium-voltage drives used on mine hoists, rolling mills and other high-power drive installations; functions as the interface between the drive’s internal protection signals (door interlocks, fault states) and the plant emergency-stop circuit.
Material Composition
Relay mechanism with force-guided contact set in a flame-retardant housing; 24 VDC coil with suppression electronics; plug-in terminal base or solder terminals depending on the panel construction.
Structure and Characteristics
Compact industrial safety relay with clearly separated coil and contact terminals, contact status indication where fitted, and mechanically linked contacts designed so that a welded contact prevents re-closure of the opposite contact set.
Working Principle
The relay energizes when the 24 VDC control supply is present and all monitored conditions are healthy, closing its force-guided outputs to enable the drive’s main contactor and control power. Any fault in the monitored circuit drops the coil; the guided contacts switch to the safe state and remove the enable signal, forcing the drive into a safe, non-operating condition.
Installation Requirements
Perform the exchange with the drive locked out and all supplies isolated. Note the wiring positions before removing the old relay, install the replacement in the same base and orientation, restore every wire to its documented terminal, and re-verify the complete safety chain function with the drive’s test procedure before releasing the equipment for production.
Precautions
Substitute only with the identical type BD 5935.48/61 24 VDC or the official successor 68711894 (BD5935.48/61-DC24), since generic relays without force-guided contacts invalidate the safety function. Test the emergency-stop loop after replacement and record the exchange in the drive’s maintenance log.

Reviews