Description
Technical Specifications
- Actuation: electrical
- Electrical I/O System: yes
- Valve Terminal Type: 32
- Operating Medium: compressed air per ISO 8573-1:2010 [7:4:4]
- Operating Pressure: -0.9 bar to 10 bar
- Pilot Pressure: 3 bar to 8 bar
- Medium Temperature: -5°C to 50°C
- Ambient Temperature: -5°C to 50°C
- Storage Temperature: -20°C to 40°C
- Relative Humidity: max. 90% at 40°C
- Protection Rating: IP67
- Nominal Voltage: DC 24 V
- Voltage Tolerance: ±25%
Performance Data
- Maximum Valve Positions: 64
- Maximum Pressure Zones: 17
- Valve Sizes: 10 mm, 14 mm, 20 mm
- Nominal Flow: 360 L/min at 10 mm, 550 L/min at 14 mm, 700 L/min at 20 mm
- Vacuum Suitable: yes
Valve Functions
- 2/2 normally closed
- 3/2 monostable and bistable variants
- 5/2 monostable and bistable
- 5/3 pressurized, exhausted and closed center
- Proportional pressure control
Structural Features
- Modular mixing of different valve sizes
- Piston slide and poppet valve design
- Internal or external pilot air supply
- LED status indication
- Fieldbus control module integration
- One-end flat plate silencer
Pneumatic Connections
- M7
- G1/8
- QS-4, QS-6, QS-8, QS-3/16, QS-1/4, QS-5/16
Material And Compliance
- RoHS compliant materials
- CE, UKCA, cULus recognized
- ATEX Zone 2, gas category II 3G
- Ex ec IIC T4 Gc X
- Corrosion resistance class CRC 1
Application Scenarios
- Factory automation
- Packaging and assembly systems
- Food and beverage process lines
- Potentially explosive industrial areas with certified configuration
Installation Requirements
- Install on clean, dry compressed air supply
- Use correct pneumatic fittings and silencers
- Ensure IP67 connector sealing
- Follow fieldbus addressing and wiring rules
Usage Notes
- Lubricated operation, once started, must be maintained
- Avoid condensation in air supply
- Check ATEX certification for hazardous zones
- Inspect seals and connectors regularly


-500x500.jpg)


Reviews