Product Short Description
Product Name
Emergency Stop Safety Relay
Product Introduction
The NST-2004 is a Category 4 safety relay module designed for emergency stop and safety gate monitoring applications. It provides 3 safety outputs and 1 signal output, with built-in short circuit monitoring and fault diagnosis functions, complying with EN ISO 13849-1 PL e standard.
Description
Technical Specifications
- Supply Voltage: 24 VDC ±10%
- Safety Category: Category 4 (PL e) according to EN ISO 13849-1
- Safety Outputs: 3 NO (Normally Open) contacts
- Signal Output: 1 NC (Normally Closed) contact or 1 transistor output
- Switching Current: 6A per safety output
- Width: 22.5 mm
- Operating Temperature: -25°C to +60°C
- Protection Class: IP20 (terminals), IP40 (housing)
- Mechanical Lifespan: 10 million operations
Functional Features
- Configurable manual or automatic reset
- Selectable short circuit protection function
- LED indicators for channel status and fault diagnosis
- Transistor output for PLC monitoring interface
- Compliance with EN 81-20/50 elevator safety standards
- Compact DIN rail mounting design
Application Scenarios
- Emergency stop button circuits in industrial machinery
- Safety light curtain and safety mat monitoring
- Elevator and lifting equipment safety control
- Packaging machine safety systems
- Conveyor line safety interlock
Material & Construction
- Housing: Flame-retardant engineering plastic
- Contacts: Silver alloy contact material
- Terminals: Nickel-plated copper terminals
- Internal circuit: SMT circuit board with conformal coating
Structural Features
- Standard 22.5mm width DIN rail housing
- Screw terminal connections for reliable wiring
- Front-facing LED status indicators
- Removable terminal blocks for easy maintenance
Working Principle
The relay adopts redundant dual-channel safety circuit design. It monitors the status of safety input devices in real time. When the safety input is triggered, both channels cut off the safety output simultaneously. The built-in self-test circuit periodically detects the internal circuit status to ensure no hidden faults, and locks the output when a fault is detected until the fault is eliminated and reset is performed.
Installation Requirements
- Install on standard 35mm DIN rail
- Ensure proper grounding of the module housing
- Separate safety wiring from power wiring to avoid interference
- Reserve at least 10mm clearance on both sides for heat dissipation
Usage Notes
- Apply only to safety circuits validated for Category 4 requirements
- Ensure the supply voltage is within the rated range
- Periodically perform functional tests of the safety circuit
- Do not modify the internal circuit or parameters without authorization