Product Short Description
Product Name
Sentron Molded Case Circuit Breaker Frame
Product Introduction
The ND63F120 is a low-voltage molded case circuit breaker frame from the Siemens Sentron series, designed for circuit protection in low-voltage power distribution systems. It provides thermal-magnetic trip protection for overload and short-circuit conditions, and complies with international safety standards for industrial power applications.
Description
Technical Specifications
- Rated Current: 1200 A
- Number of Poles: 3
- Rated Voltage: 600 V AC
- Short-Circuit Breaking Capacity: 25 kAIC at 600V, 50 kAIC at 480V
- Trip Unit Type: Thermal-Magnetic
- Standard Compliance: UL 489, IEC 60947-2
- Wire Range: 250 – 500 KCM (copper/aluminum)
- Dimensions (W x H x D): 9 in × 16 in × 6 in
- Weight: Approximately 21.68 kg
Functional Features
- Standard breaking capacity for general industrial power distribution
- Line and load side lugs for convenient conductor connection
- Reliable thermal-magnetic trip mechanism with accurate protection characteristics
- Robust housing structure for harsh industrial environments
- Full compatibility with ND series circuit breaker accessories
Application Scenarios
- Industrial plant main power distribution panels
- Motor control center (MCC) feeder circuits
- Commercial building low-voltage switchgear
- Heavy machinery power input protection
- Data center power distribution systems
Material & Construction
- High-strength thermoset insulating housing
- Copper current-carrying conductors with silver-plated contacts
- Alloy steel operating mechanism with high mechanical durability
- Arc extinguishing chamber with grid plate structure
Working Principle
Under normal operating conditions, the breaker conducts current continuously. When an overload occurs, the bimetallic strip in the thermal unit heats and deflects to trigger the trip mechanism. In case of a short circuit, the magnetic coil generates instantaneous electromagnetic force to actuate the trip mechanism, rapidly separating the contacts and interrupting the fault current.
Installation Requirements
- Mount vertically in switchgear or distribution panels
- Torque terminal connections to manufacturer-specified values
- Ensure sufficient phase-to-phase and phase-to-ground clearance
- Install in an environment with ambient temperature between -30°C and +70°C
- Secure mounting with appropriate mounting hardware
Usage Notes
- Do not exceed the rated voltage and short-circuit breaking capacity
- Periodically inspect contact condition and operating mechanism
- Ensure proper torque on all conductor connections to prevent overheating
- Do not modify the trip unit settings without authorization
- Follow lockout/tagout procedures before performing maintenance