Product Short Description

Product Name:​ Eaton Cutler-Hammer XT Series IEC Magnetic Contactor (27 mm frame, non-reversing)
Product Introduction:​ The E111A12X3N is a full-voltage, non-reversing magnetic contactor from Eaton’s Cutler-Hammer XT IEC series, designed for switching three-phase motors and resistive loads in industrial control panels.
Technical Specifications:
  • Type:​ Full voltage, non-reversing magnetic contactor

Description

  • Frame Size:​ 27 mm
  • Poles:​ 3 poles
  • Rated Current:​ 12 A at 480 V AC (AC-3 duty); 20 A at 480 V AC (AC-1 duty)
  • Coil Voltage:​ 24 V DC
  • Power Rating:
    • 3 kW at 220/240 V, 50/60 Hz, 3-phase
    • 5.5 kW at 380/400/415/440/460/500/550/575 V, 50/60 Hz, 3-phase
    • 1/2 HP at 115/120 V, 50/60 Hz, 1-phase
    • 2 HP at 220/230 V, 50/60 Hz, 1-phase
    • 3 HP at 200/208/230/240 V, 50/60 Hz, 3-phase
    • 5 HP at 380/415 V AC, 50/60 Hz, 3-phase
    • 7.5 HP at 460/575 V, 50/60 Hz, 3-phase
  • Applicable Standards:​ IEC 60947-4-1, EN 60947-4-1, UL 508, CSA C22.2
  • Approvals:​ UL, CSA, CE
  • Enclosure Type:​ Open type (intended for panel mounting)
  • Mechanical Life:​ ≥ 10 million operations
  • Electrical Life:​ ≥ 1 million operations (at AC-3 rating)
  • Operating Frequency:​ 1200 operations/hour (standard duty)
  • Working Temperature:​ -40 to +65 °C
  • Dimensions:​ 130 mm (W) × 143 mm (D) × 102 mm (H)
  • Weight:​ Approximately 0.35 kg (0.77 lb)
Functional Features:
  • Compact 27 mm frame design for high-density control panels
  • Built-in coil controller (factory-assembled for 27 mm and 140 mm frames) simplifying wiring
  • Full voltage switching of three-phase loads
Application Scenarios:​ Motor starting and control for pumps, fans, conveyors, and assembly line machinery; general purpose AC load switching in industrial automation control cabinets.
Working Principle:​ When 24 V DC is applied to the coil, an electromagnetic field pulls the moving contacts toward the fixed contacts, closing the three main poles and allowing current to flow to the load. Removing coil voltage releases the armature via spring force, opening the contacts and de-energizing the load.
Installation Requirements:​ DIN rail mounting in a standard industrial control cabinet. Connect the three-phase load to the main power terminals and apply 24 V DC to the coil terminals. Ensure proper torque on all terminal screws.
Usage Precautions:​ Do not exceed 12 A at AC-3 or 20 A at AC-1. The contactor is open-type—it must be installed inside a cabinet with appropriate overload protection (such as a motor overload relay). Verify coil voltage is exactly 24 V DC. Maintain ambient temperature within -40 to +65 °C.