Product Short Description
Product Name: X-Series Lynx 101-Segment Bargraph Panel Meter (being discontinued; replacement model: FL-B101Q)
Product Overview: The FX-B101Q is a 144 × 36 mm Lynx-family bargraph panel meter with a 101-segment display. It accepts a wide range of input modules (33+ AC/DC voltage, current, process, thermocouple, RTD, load cell, pressure, resistance, position, line frequency) and optionally provides an isolated 16-bit 4–20 mA or 0–10 V DC analog output. Variants include FX-B101Q-ACA (AC Amps), -ACV (AC Volts), -DCA (DC Amps), -DCV (DC Volts) and -HZ (Frequency).
Description
Technical Specifications:
- Display: 101-segment bargraph
- Case Size: 9/64 DIN, 144 × 36 mm bezel; depth behind bezel 117.5 mm (plus 10 mm for right-angle connector or 18.3 mm for straight-through connector)
- Power Supply: 85–265 V AC / 95–300 V DC, or 15–48 V AC / 10–72 V DC
- Optional Analog Output: 4–20 mA or 0–10 V DC, isolated, 16-bit
- Measurements Supported: DC Voltage, DC Current, AC Voltage, AC Current, Process, Thermocouple, RTD, Load Cell, Pressure, Resistance, Position, Line Frequency
- Operating Temperature: 0 to 50 °C
- Storage Temperature: –20 to 70 °C
- Relative Humidity: 95% (non-condensing)
- Country of Origin: USA
- Certifications: UL, CE, RoHS, BABA (Made in USA)
- Programming: Texmate Quickset (direct front-panel button adjustment, no menus)
Key Features: 101-segment bargraph for at-a-glance indication; plug-in I-Series input modules covering 33+ signal types; optional isolated 16-bit analog output for retransmission; Quickset programming for rapid, menu-free setup; wide AC/DC auto-sensing power supply; UL/CE/RoHS/BABA compliant.
Working Principle: The selected I-Series input module conditions the field signal and feeds the meter’s A/D stage. The 101-segment bargraph displays the processed value; the optional isolated output module provides a 4–20 mA or 0–10 V DC retransmission signal for SCADA or recording.
Application Scenarios: Power generators and retrofit analog switchboard meters (AC Amps/Volts variants); DC voltage/current monitoring; process signal (4–20 mA, 0–10 V) display; thermocouple/RTD temperature indication; load-cell and pressure indication; line-frequency monitoring.
Installation Requirements: Cut a 9/64 DIN (144 × 36 mm) panel aperture; insert the meter from the front and secure; select and insert the appropriate I-Series input module; connect field wiring per the module’s terminal diagram; provide 85–265 V AC / 95–300 V DC or 15–48 V AC / 10–72 V DC supply; for the analog output option, wire the isolated 4–20 mA or 0–10 V DC to the recording/control device.
Usage Notes: The FX-B101Q is being discontinued — finite quantity in stock; the replacement model is FL-B101Q. Verify the correct variant suffix (ACA, ACV, DCA, DCV, HZ) matches the measured signal. Use Quickset front-panel buttons for fast scaling and zero adjustment; refer to the FX-B101Q manual for detailed module compatibility.