Product Short Description
Product Name: KEBA FM265/A KeConnect C2 PROFIBUS DP Slave Communication Module
Product Introduction: The FM265/A is a PROFIBUS DP slave communication module belonging to KEBA’s KeConnect C2 product line. It enables the exchange of cyclic process data and acyclic parameter data between a KeControl C2 controller (e.g., CP033/Y) and any PROFIBUS DP slave devices such as sensors, drives, and I/O stations. The module attaches directly to a CPU module or operates with all KEBA controls via bus couplers.
Description
Technical Specifications:
- Model: FM265/A
- Order number: 067215
- Manufacturer: KEBA AG
- Type: PROFIBUS DP-V1 slave communication module
- Transmission rate: 9.6 kbit/s to 12 Mbit/s (max 12 Mbit/s)
- Max line length: 100 m at 12 Mbit/s; up to 1200 m at 9.6 kbit/s
- Supply voltage: 24 Vdc (±10%) via K-bus; 5 V from K-bus
- Current consumption: ≤ 0.25 A (≈ 6 W)
- Isolation: 500 V AC (bus vs. internal electronics)
- Galvanic isolation: Yes, on signal lines
- Data exchange: Cyclic process data + acyclic parameter data
- Parameter storage: Electronic parameter chip (battery-free)
- Protection: Overvoltage, reverse polarity, ESD, short-circuit
- Dimensions (W × H × D): 22.5 × 120 × 100 mm (front plate 22.5 mm; 32.5 mm incl. K-bus plug)
- Weight: 135–140 g
- Protection class: IP20
- Mounting: KEBA K2/C2 backplane / DIN rail
- Operating temperature: +5°C to +55°C
- Storage temperature: -40°C to +70°C
- Relative humidity: 10% to 95% (non-condensing)
- Altitude: ≤ 2000 m
- Vibration/shock: Compliant with EN 61131-2
- EMC: 2004/108/EC, EN 55022, EN 55024
- Safety: EN 61131-2, Protection Class III
Front-panel LEDs:
- PWR: Green (power on)
- RUN: Green (running; blinking = startup)
- FLT: Red (fault)
- BUS: Yellow (PROFIBUS activity)
Functional Features:
- PROFIBUS DP-V1 slave interface with up to 12 Mbit/s
- High interference immunity with galvanic isolation
- Battery-free electronic parameter chip for configuration storage
- Direct attachment to KEBA C2/K2 CPU modules
- Full diagnostics via front-panel LEDs
- Configurable via KEBA KAS IDE software
- Compatible with a wide range of PROFIBUS DP slave devices
Application Scenarios: Connecting KeControl C2/K2 controllers to PROFIBUS DP networks in industrial automation; interfacing sensors, drives, and I/O stations to KEBA control systems; machine automation, packaging machinery, and robotics where PROFIBUS DP connectivity is required.
Installation Requirements: Attach directly to a compatible KEBA C2/K2 CPU module backplane, or mount on a DIN rail with a bus coupler. The module draws 24 Vdc and 5 V from the K-bus — no external power supply is needed. Configure the PROFIBUS address via KAS IDE software. Maintain clearance for air circulation.
Usage Precautions: Operating temperature must be kept within +5°C to +55°C. The module is IP20 — install inside a suitable control cabinet. The maximum of one FM265/A can be operated on a single CPU module. Ensure proper PROFIBUS termination at network endpoints. Reverse polarity and overvoltage protection are built-in, but correct wiring is still required to avoid bus faults.