Product Short Description

Product Overview

VE4003S3B1 is passive field wiring terminal base for DeltaV Classic I/O system. It provides wiring interface between field instruments and analog input module, transmits analog signals without signal conversion function. It supports fixed wiring so users can pre-wire field cables before installing I/O modules.

Description

Technical Specifications

  • Signal Type: Analog millivolt voltage signal routing
  • Terminal Quantity: Corresponding wiring terminals for 8-channel analog input
  • Operating Temperature: -40 °C ~ +70 °C
  • Storage Temperature: -40 °C ~ +85 °C
  • Humidity Range: 5% ~ 95% relative humidity, non-condensing
  • Protection Class: IP20
  • Allowable Wire Gauge: 0.5 mm² ~ 2.5 mm² (20 AWG ~ 14 AWG)
  • Recommended Terminal Torque: 0.6 N·m ~ 0.8 N·m
  • Dimension: 107 mm × 41 mm × 105 mm
  • Weight: 0.28 kg
  • Environmental Grade: ISA-S71.04 Class G3

Functional Features

  1. Passive signal routing, no power consumption
  2. Captive terminal screws to prevent screw loss
  3. Unique mechanical keying system to avoid mismatched I/O module installation
  4. Clear channel marking for convenient wiring inspection
  5. Supports pre-wiring, reduces field construction downtime
  6. Compatible with hot swap of upper I/O modules without disconnecting field wiring

Working Principle

Field sensor cables connect to screw terminals of termination block. Metal conductive strips inside the base transmit raw analog signals directly to the plugged I/O module. No signal amplification, conversion or processing occurs inside the termination block.

Material Composition

  • Housing: Flame-retardant thermoplastic
  • Conductive terminals: Tin-plated copper alloy
  • Internal bus bar: Copper alloy
  • Fasteners: Stainless steel screws

Structural Characteristics

  • Snap-on structure for DeltaV I/O carrier
  • Rear male connector for plugging with I/O module
  • Front side screw terminal row for field wiring
  • Rotatable coding pins for function matching lock

Application Scenarios

Support terminal wiring for analog input modules in DeltaV distributed control system, applied in chemical, oil & gas, energy, pharmaceutical, water treatment and other process industries. Matched with low-level signal input modules such as thermocouple and mV input modules.

Installation Requirements

  1. Mount termination block onto DeltaV Classic I/O carrier fixed on DIN rail
  2. Arrange signal cables separately from power cables inside cabinet
  3. Reserve maintenance space in front of terminal block for wiring inspection
  4. Complete all wiring before installing corresponding I/O module
  5. Follow plant unified grounding specification for cable shield connection

Usage Notes

  1. Do not exceed rated wire size for each terminal
  2. Avoid placing termination block at positions with direct air flow of cooling fan
  3. Prevent conductive dust, moisture and corrosive gas accumulation inside cabinet
  4. Check terminal tightness periodically during scheduled maintenance
  5. Observe ESD protection when installing adjacent electronic modules
  6. Do not connect AC high voltage signal to analog signal terminals