Product Short Description

Product Introduction

L015015 is an industrial galvanometer laser scan head manufactured by Domino Printing Sciences, matched exclusively to D-Series CO₂ laser coding/marking controllers. It delivers high-speed 1D/2D barcode, text and graphics marking on packaging production lines for permanent product traceability coding.

Description

Technical Specifications

  • Laser Wavelength Compatibility: 10.6 μm CO₂ laser
  • Standard Marking Field of View: 80mm × 80mm (8mm focal i-Tech optical lens)
  • Max Marking Speed: 60,000 products per hour continuous operation
  • Operating Temperature Range: +5°C ~ +40°C
  • Storage Temperature Range: -20°C ~ +60°C
  • Humidity Tolerance: Max 90% RH non-condensing
  • Enclosure Protection Rating: IP55 industrial sealed housing
  • Input Power Supply: 24 V DC ±5%, 1.2 A max current draw
  • Communication Interface: High-speed differential signal cable to D-series laser controller
  • Galvanometer Scan Response Time: ≤0.3 ms full field positioning
  • Total Unit Weight: 2.27 kg (5.00 lbs)

Function Features

  1. High-speed galvanometer mirror scanning for high-throughput packaging line marking
  2. Integrated optical alignment calibration port for on-site marking field adjustment
  3. IP55 fully sealed aluminum housing resists production line water washdown and dust ingress
  4. Built-in temperature sensor to monitor scan head internal temperature and trigger overheat protection
  5. Native compatibility with Domino QuickStep2 marking software for dynamic serial number, date and GS1 barcode generation

Performance Parameters

  • Marking resolution: 0.05mm minimum line width
  • Supported code types: 60+ varieties of 1D barcodes, QR, Data Matrix, PDF417 2D codes
  • Continuous operation duty cycle: 100% non-stop 24-hour production line operation
  • Optical positioning repeatability: ±0.01 mm
  • Galvanometer mirror service life: ≥20,000 operating hours
  • Overheat protection trigger temperature: 42°C internal housing temperature

Material Composition

  • Main housing: Die-cast anodized aluminum alloy
  • Optical window: Anti-reflection coated zinc selenide (ZnSe) laser transmission glass
  • Galvanometer mirror: Gold-coated high-reflectivity optical glass
  • Internal wiring: PTFE high-temperature insulated shielded cable
  • Sealing components: EPDM high-temperature resistant rubber gaskets
  • Mounting bracket: Stainless steel 304 adjustable fixture

Structural Characteristics

  • Compact rectangular sealed monoblock housing design
  • Single integrated optical lens window at front marking output face
  • Rear panel dedicated power connector and differential signal communication connector
  • Top surface laser warning safety label (Class 1 laser equipment)
  • Multi-axis adjustable stainless steel mounting bracket pre-installed
  • Internal heat sink aluminum fin structure for passive heat dissipation

Working Principle

CO₂ laser beam transmitted from laser controller enters scan head optical cavity; dual galvanometer X/Y mirrors deflect laser beam according to digital positioning signals from controller to draw pre-programmed text, barcode or graphic patterns on target product surface. Built-in temperature sensor monitors internal heat accumulation and sends overheat alarm signal to controller to pause marking process and prevent galvanometer damage.

Advantage Highlights

  1. IP55 washdown-rated housing compatible with food, beverage and pharmaceutical production line cleaning cycles
  2. Fast galvanometer response enables high-speed packaging conveyor line integration
  3. Anti-reflection coated ZnSe lens reduces laser power loss and improves marking contrast
  4. Integrated temperature monitoring eliminates thermal drift marking distortion
  5. Full software integration with Domino industrial coding systems for traceability compliance

Applicable Industries

Food & beverage packaging, pharmaceutical blister and carton coding, tobacco packaging, cosmetic container marking, building materials traceability coding

Installation Requirements

  1. Mount scan head bracket to rigid production line frame with M6 stainless steel bolts torqued to 1.2 N·m
  2. Maintain minimum 150mm unobstructed vertical distance between scan head window and product marking surface
  3. Route signal/power cable with minimum 50mm bend radius to avoid internal wire breakage
  4. Install forced ambient air cooling fan if production line ambient temperature exceeds 35°C
  5. Align optical marking field via calibration port after mechanical mounting adjustment

Usage Precautions

  1. Never clean optical window with dry cloth; use dedicated Domino lens cleaning fluid and lint-free tissue only
  2. Avoid direct mechanical impact to front optical window to prevent coating scratch damage
  3. Do not operate scan head above 40°C ambient temperature; permanent galvanometer drift will occur
  4. Schedule monthly optical window inspection to remove packaging dust and liquid residue
  5. Disconnect 24V DC power supply before removing mounting bracket for maintenance