Product Short Description

Product Name: Schneider Electric AS-B836-016 – Modicon M340 I/O Module, 16 Digital Outputs, 24 V DC Transistor

Product Overview:
The AS-B836-016 is a 16-channel digital output module for the Modicon M340 PLC platform. Provides transistor-type sinking outputs for fast-switching DC loads.

Description

Technical Specifications:

Parameter Value
Channels 16 digital outputs
Output Type Transistor, sinking (NPN)
Output Voltage 24 V DC (nominal)
Max Current per Channel 0.5 A
Total Module Current 4 A (shared)
Response Time (ON→OFF) 0.2 ms typical
Response Time (OFF→ON) 0.2 ms typical
Isolation Voltage 500 V AC (channel-to-channel)
Power Consumption 1.8 W (bus) + load
Mounting DIN rail / backplane (M340 bus)
Operating Temperature 0°C to +60°C
Standards IEC 61131-2, CE, UL 508

Functional Features:

  • 16 independent transistor outputs
  • Common ground (sinking) configuration
  • Status LED per group of 4 channels
  • Diagnostic LED for module fault
  • Hot-swap capable on M340 backplane

Material Composition:

  • Housing: Polycarbonate (PC) – UL94 V-0
  • PCB: FR-4, gold-plated contacts
  • Connectors: Spring-clip terminals (push-in)
  • Isolation: Optocouplers per channel group

Structural Features:

  • Front-connectable via spring terminals
  • Group-wise LED indicators (4 channels per LED)
  • DIN rail clip included
  • 40 mm module width

Working Principle:
PLC sends logic signal → optocoupler isolates → transistor switches ON → current flows from load through output to common ground. Group diagnostic monitors for overcurrent/short-circuit.

Advantages:

  • Ultra-fast switching (0.2 ms) for high-speed applications
  • Individual channel isolation via optocouplers
  • Front wiring saves installation time

Applicable Industries:

  • Packaging machinery
  • Assembly lines
  • Material handling
  • Process automation

Installation Requirements:

  • M340 backplane or DIN rail mounting
  • Wire gauge: 0.5–2.5 mm² for signal, 0.5–1.5 mm² for power
  • Max cable length to load: 100 m (at 0.5 A)

Usage Notes:

  • Do not exceed 0.5 A per channel or 4 A total
  • Use flyback diode for inductive loads (solenoids, relays)
  • Ensure common ground is connected to 0 V DC

Reviews

There are no reviews yet.

Be the first to review “Schneider AS-B836-016”

Your email address will not be published. Required fields are marked *

View Related Products