Product Short Description

The GE IC670ALG240‑JC is a high‑density, high‑precision 16‑channel analog current input module from the GE Fanuc (Emerson) Field Control I/O series, designed for distributed industrial control systems. It interfaces directly with 2‑wire or 3‑wire industrial transmitters and sensors, converting 0–20mA or 4–20mA analog current signals into 16‑bit digital values for PLC or host controller processing. The “JC” suffix denotes factory calibration, extended environmental screening, and full compliance with global industrial standards.

Description

Technical Specifications

  • Manufacturer: General Electric (GE Fanuc / Emerson Automation Solutions)
  • Series: Field Control (Distributed I/O System)
  • Model: IC670ALG240‑JC
  • Input Channels: 16 single‑ended, grouped in one common power supply group
  • Input Signal Ranges: Configurable 0–20mA, 4–20mA; absolute maximum 0–25mA
  • Resolution: 16‑bit (0.00015mA per bit typical)
  • Accuracy: ±0.05% of full scale at 25°C; ±0.1% over operating temperature range
  • Input Impedance: 250 Ohms per channel
  • Data Acquisition Rates: 100Hz (10ms) for 50Hz line; 120Hz (8.33ms) for 60Hz line
  • Digital Filtering: Selectable 10ms or 20ms per channel
  • Calibration: Factory calibrated; user‑recalibratable in field; calibration stored in FLASH memory
  • Power Requirements: 20–28VDC (nominal 24VDC); 251mA maximum current draw from BIU
  • LED Indicators: Module OK, Power, Fault, and Channel Status
  • Operating Temperature: 0°C to +55°C (32°F to 131°F)
  • Storage Temperature: -40°C to +85°C (-40°F to 185°F)
  • Relative Humidity: 5%–95%, non‑condensing
  • Dimensions (H×W×D): 127mm × 96.8mm × 82.6mm (5.0in × 3.81in × 3.25in)
  • Weight: 0.79kg (1.74lbs)
  • Mounting: Field Control I/O base (e.g., IC670CHS002E)
  • Certifications: CE, UL 508, CSA C22.2 No. 142, Class I Div 2 Groups A, B, C, D hazardous location rated

Key Features

  1. 16‑Channel High‑Density Input: Provides 16 analog current inputs in a compact form factor, reducing cabinet space and wiring complexity for large I/O count systems.
  2. 16‑Bit High Precision: Delivers 16‑bit resolution and ±0.05% full‑scale accuracy, ensuring precise measurement of small signal variations for critical process control.
  3. Configurable Signal Ranges: Supports both 0–20mA and 4–20mA standard industrial current loops, compatible with a wide range of transmitters and sensors.
  4. 2‑Wire/3‑Wire Transmitter Support: Accepts inputs from ANSI Type 2 2‑wire and 3‑wire current transmitters, offering flexibility in field wiring and sensor selection.
  5. User‑Configurable Digital Filtering: Selectable 10ms or 20ms filtering per channel eliminates electrical noise and signal fluctuations in harsh industrial environments.
  6. Onboard Diagnostics & Alarms: Real‑time detection of module faults, calibration errors, A/D conversion failures, overrange/underrange conditions, and open‑wire faults; reports via LED indicators and bus communication.
  7. Non‑Volatile Calibration: Factory calibration stored in FLASH memory; user recalibration allowed without external tools, ensuring long‑term stability and accuracy.
  8. Line Frequency Synchronization: Data acquisition rates synchronized to 50Hz or 60Hz line frequency, minimizing power‑line interference.
  9. Hazardous Location Compliance: UL/CSA Class I Div 2 rated for safe operation in explosive atmospheres (oil and gas, chemical processing).
  10. Robust Industrial Design: Rugged construction, wide operating temperature range, and noise immunity ensure reliable 24/7 operation in harsh manufacturing and process environments.

Applications

  • Process Control: Chemical, petrochemical, water treatment, and pharmaceutical plants monitoring pressure, level, flow, temperature, and turbidity via 4–20mA transmitters.
  • Factory Automation: Automotive assembly, food and beverage processing, and packaging machinery requiring high‑density analog input for process variables.
  • Oil & Gas: Offshore/onshore facilities, pipelines, and refineries monitoring wellhead pressure, flow rates, and tank levels in hazardous areas.
  • Building Automation: HVAC systems, energy management, and environmental monitoring in large commercial and industrial facilities.
  • Power Generation: Thermal, hydro, and renewable power plants monitoring boiler temperature, steam pressure, and generator output.
  • Legacy System Upgrades: Replacement or expansion of existing Field Control I/O systems, maintaining compatibility with installed BIUs and bases.

Compatibility

  • Field Control Bases: IC670CHS002E (2‑tier box terminal), IC670CHS001E (1‑tier)
  • Bus Interface Units (BIU): IC670BIU001, IC670BIU002, IC670BIU003
  • Programming Software: Proficy Machine Edition (PME), Field Control Configuration Software
  • Replacement Model: IC670ALG240 (standard calibration, non‑JC suffix)

Reviews

There are no reviews yet.

Be the first to review “GE IC670ALG240-JC Field Control 16‑Point Current Source Analog Input Module”

Your email address will not be published. Required fields are marked *

View Related Products