Product Short Description
Product Overview
The 3BHB014827R0001 is a closed-loop Hall-effect current transducer, LEM type LT 2005-S/SP19, supplied by ABB as an original spare part for its medium-voltage variable-frequency drives. It is documented for use in ACS 6000 variator applications and the ACS6114 drive series, where it performs precise current measurement inside the converter power stage.
Description
Technical Specifications
Device type: current transducer, closed-loop Hall-effect design, LEM LT 2005-S/SP19. Primary rated current 2000 A class with high overload capability; the LT 2005-S series provides galvanically isolated current measurement with a low-level secondary signal for control electronics. Supply and output electronics powered from the drive’s ±15 V (typical) measurement supply. Panel/cubicle designations documented for the device include 20200-SEL-011, 20230-SEL-010, 63411-SEE-001 and 68441-SEE-001 in ACS6000 installations.
Functional Features
Galvanic isolation between the high-voltage power circuit and the low-voltage control electronics; closed-loop Hall architecture delivering high accuracy, fast response and excellent linearity over the full current range; immunity to drive switching noise through shielded construction; compact frame-mount package suitable for busbar primary passing.
Applications
Phase-current measurement in ABB ACS 6000 and ACS6114 medium-voltage drive converters, feeding the actual-current feedback to the inverter control for current regulation, torque control, overcurrent protection and ground-fault monitoring; equally applicable in other ABB MV drive frames using the same measurement chain.
Material Composition
Precision Hall sensor with magnetic core and compensation winding inside an epoxy-sealed housing; secondary connector for the measurement cable to the control electronics; primary formed by a busbar or cable passing through the transducer aperture.
Structure and Characteristics
Rectangular frame-type package in which the primary conductor passes through the magnetic circuit opening; the secondary side carries the compensation winding and a dedicated connector for the control wiring. The device is fixed to the converter’s busbar assembly inside the power cubicle.
Working Principle
The primary current creates a magnetic flux in the core; the Hall element detects any imbalance and drives a compensation current through the secondary winding that exactly cancels the flux. This secondary current is an exact, isolated replica of the primary current and is converted by a measuring resistor into a voltage proportional to the line current for the drive controller.
Installation Requirements
De-energize and lock out the drive, discharge the DC link, remove the control-connector, unbolt the transducer from the busbar assembly, fit the new unit with the correct mounting orientation and torque, reconnect the secondary cable with proper shielding, and verify the measuring resistor and calibration values in the drive parameters before restart.
Precautions
Never open-circuit the secondary side while primary current flows, since this drives the transducer into saturation and produces hazardous voltages and false measurements. Confirm the exact type LT 2005-S/SP19 and order number 3BHB014827R0001 when ordering, keep the connector and shielding intact to preserve noise immunity, and verify zero-current output offset after replacement as part of the drive’s measurement-chain check.
Additional information
| Weight | 2 kg |
|---|---|
| Dimensions | 100 × 30 cm |





Reviews
There are no reviews yet.