Product Short Description

Product Overview

TRICONEX 2401 is a core safety-grade digital output baseplate module developed by Honeywell TRICONEX. It belongs to the Trident series TMR (Triple Modular Redundancy) safety control system. This module undertakes stable digital signal output control for safety-critical industrial sites. It realizes driving control for on-site valves, actuators, relays and interlock execution equipment. It adopts full hardware triple redundancy architecture, built-in comprehensive self-diagnosis, fault isolation and fail-safe functions.

Description

Technical Specifications

Basic Hardware Parameters

  • Manufacturer: TRICONEX (Honeywell Group)
  • Product Type: Digital Output (DO) Baseplate Module
  • Redundancy Architecture: Full Triple Modular Redundancy (TMR)
  • Safety Integrity Level: SIL3 Certified
  • Rated Supply Voltage: 24 V DC
  • Total Power Consumption: 5 W
  • Single Channel Rated Output Current: 500 mA
  • Digital Output Channels: 16 independent monitored output channels
  • Output Signal Type: Dry contact / 24VDC switching signal
  • Channel Isolation: Complete electrical isolation between channels and system bus

Environmental Specifications

  • Operating Ambient Temperature: -40 ℃ to +70 ℃
  • Storage Temperature: -40 ℃ to +85 ℃
  • Protection Grade: IP67 (dustproof, waterproof, vibration-resistant)
  • Anti-interference Performance: Meet industrial EMC electromagnetic compatibility standards
  • Module Dimensions: 236 mm × 136 mm × 106 mm
  • Module Weight: 1.2 kg

Communication & Interface Specifications

  • On-board Communication Interfaces: RS-232, RS-485
  • Supported Protocols: Modbus RTU, TRICONEX proprietary system bus, Ethernet optional expansion
  • Backplane Bus: TRICONEX high-speed redundant safety bus
  • Field Wiring Terminal: Standard screw-type industrial terminal block

Fault & Response Specifications

  • Built-in Diagnosis Cycle: Real-time continuous diagnosis (60s full system self-check cycle)
  • Fault Switching Response Time: ≤5 seconds
  • Fault Detection Content: Open circuit, short circuit, overvoltage, channel abnormal output
  • Fail-safe Mechanism: Automatic safe shutdown of faulty channel, system maintains normal operation
  • Maintenance Mode: Support hot plug & hot swap, no system power-off required for replacement

Functional Characteristics

1. Ultimate TMR Triple Redundancy Reliability

Three completely independent control circuits collect, calculate and output signals simultaneously. Cross majority voting logic eliminates single channel failure influence. Single module or single channel fault will not cause system control failure or safety function loss.

2. Full-range On-line Self-diagnosis & Fault Isolation

Real-time monitoring of output channel status, power supply, bus communication and hardware circuit. Automatically locate faulty channel, isolate fault output and send alarm signal. Normal channels keep working continuously.

3. Complete Fail-safe Safety Design

Strictly comply with safety instrumented system logic. When module detects abnormal fault, output automatically switches to predefined safe state immediately. Effectively avoid dangerous false output in industrial high-risk scenarios.

4. High Stability Anti-interference Performance

Adopt isolated power supply, isolated signal circuit and anti-surge protection circuit. Effectively resist industrial electromagnetic interference, voltage fluctuation and harsh on-site electrical noise.

5. Convenient Maintenance & High Scalability

Modular standardized structure, hot pluggable design. Support free expansion matching with TRICONEX Trident/Tricon series controllers. Simple wiring, convenient configuration and on-site debugging.

6. Precise Monitored Output Control

Each output channel has independent status feedback monitoring. Realize closed-loop verification of output execution status, ensure consistent output instruction and on-site equipment action.

Application Scenarios

Petrochemical Industry

Applied to reactor pressure/temperature safety interlock, emergency shutdown ESD system, pipeline valve safety control, flare system interlock control. Realize high-risk process safety protection and accident prevention.

Power Generation Industry

Used for steam turbine ESD shutdown control, boiler burner management BMS system, generator unit safety interlock, grid-connected safety protection and abnormal condition emergency stop control.

Metallurgy & Chemical Processing Industry

Applied to smelting furnace safety interlock, production line emergency stop, high-temperature pressure equipment safety monitoring and execution control.

Natural Gas & Oil Storage & Transportation

Used for pipeline pressure interlock, station valve safety control, leakage emergency shutdown and gas distribution safety instrumented system.

Other Safety-critical Industrial Fields

Including pharmaceutical fine chemical industry, water treatment safety interlock, large industrial compressor unit safety control and all industrial occasions requiring SIL3 level safety output control.

Reviews

There are no reviews yet.

Be the first to review “TRICONEX 2401”

Your email address will not be published. Required fields are marked *

View Related Products